| 1 | **Description**: Learn how to receive, inspect, unpack, move, and install the Auto-Light before commissioning. Apply the same checks after any relocation. | ||
| 2 | |||
| 3 | {{toc/}} | ||
| 4 | |||
| 5 | (% class="box errormessage" %) | ||
| 6 | ((( | ||
| 7 | **Class 4 integration laser: **Transportation and installation may be performed only by qualified personnel. Do not apply power until the Auto-Light and the host machine have been mechanically and electrically installed and all required laser-safety measures are ready for validation. | ||
| 8 | ))) | ||
| 9 | |||
| 10 | ---- | ||
| 11 | |||
| 12 | = Delivery Inspection = | ||
| 13 | |||
| 14 | Inspect the shipment immediately after unloading and before installation: | ||
| 15 | |||
| 16 | * Check the Auto-Light and all supplied components for visible transport damage. | ||
| 17 | * Check accessible screws and threaded connections for signs of movement or loosening. | ||
| 18 | * Compare the shipment with the order and delivery documents; the actual configuration and options may differ from the manual's standard-configuration list. | ||
| 19 | * If anything is damaged or missing, record it in writing, note it on the freight documents, take photographs, and send the report to Schilling Marking Systems. | ||
| 20 | |||
| 21 | (% class="box warningmessage" %) | ||
| 22 | ((( | ||
| 23 | **Protect the optics: **Keep the lens-unit or objective protection cover installed until the marking head is in its final installed position. Clean, undamaged optics are required for correct marking performance | ||
| 24 | ))) | ||
| 25 | |||
| 26 | |||
| 27 | |||
| 28 | = External Transportation = | ||
| 29 | |||
| 30 | * Keep the carton upright and firmly secured to the pallet. | ||
| 31 | * Secure the palletised shipment against sliding and tipping throughout transport. | ||
| 32 | * Use a forklift suitable for the weight and delivered configuration when unloading the palletised carton. | ||
| 33 | * Protect the shipment from strong vibration, shock, contamination, and weather exposure. | ||
| 34 | |||
| 35 | |||
| 36 | |||
| 37 | = Unpacking = | ||
| 38 | |||
| 39 | Two qualified people are required to remove the transport packaging. | ||
| 40 | |||
| 41 | 1. Place the carton and pallet upright on level ground using a suitable forklift. | ||
| 42 | 1. Stabilise the load, then release the black tensioning straps. | ||
| 43 | 1. Remove the carton and packing sections carefully so that no section tips or falls. | ||
| 44 | 1. Remove the remaining packaging and transport restraints only when the equipment is supported and ready for installation. | ||
| 45 | 1. Retain reusable packaging and every delivered transport restraint for future shipment or long-distance relocation. | ||
| 46 | |||
| 47 | (% class="box warningmessage" %) | ||
| 48 | ((( | ||
| 49 | **Handling rule: **Keep the Auto-Light upright. Avoid mechanical loads, vibration, and impact; the system contains high-quality electrical and optical components. | ||
| 50 | ))) | ||
| 51 | |||
| 52 | |||
| 53 | |||
| 54 | = In-Plant Transportation = | ||
| 55 | |||
| 56 | 1. Stop the process and set the rear main switch to 0 (OFF). | ||
| 57 | 1. Disconnect the electrical supply cable. | ||
| 58 | 1. Disconnect and remove the extraction system where fitted, following the extraction supplier's instructions. | ||
| 59 | 1. Keep the equipment upright and slightly lift the supported assembly with handling equipment suitable for its weight and configuration. | ||
| 60 | 1. Move it without strong vibration or shock and place it on a level, clean installation surface. | ||
| 61 | 1. After relocation, realign the system, repeat the initial electrical commissioning procedure, and perform a controlled functional test. | ||
| 62 | |||
| 63 | |||
| 64 | |||
| 65 | = Installation-Site Requirements = | ||
| 66 | |||
| 67 | (% class="table-condensed table-striped" style="width:1272px" %) | ||
| 68 | |(% style="width:299px" %)**Requirement**|(% style="width:971px" %)**Installation criterion** | ||
| 69 | |(% style="width:299px" %)Environment|(% style="width:971px" %)+15 °C to +35 °C; relative humidity no higher than 90%, non-condensing. | ||
| 70 | |(% style="width:299px" %)Acclimatisation|(% style="width:971px" %)After a major temperature change, allow the equipment to return to room temperature before commissioning. | ||
| 71 | |(% style="width:299px" %)Support|(% style="width:971px" %)Upright, level, clean, stable, and suitable for the delivered configuration. | ||
| 72 | |(% style="width:299px" %)Cooling|(% style="width:971px" %)Provide adequate air to both 19-inch rack units; keep ventilation openings and filter mats unobstructed. | ||
| 73 | |(% style="width:299px" %)Extraction|(% style="width:971px" %)Provide extraction suitable for the gases, vapours, aerosols, and dust generated by the material and process. | ||
| 74 | |(% style="width:299px" %)Safety|(% style="width:971px" %)Complete the host enclosure, access control, emergency-stop functions, shutter interlocks, emission warning, and other required safeguards. | ||
| 75 | |||
| 76 | |||
| 77 | |||
| 78 | = Placement and Service Clearance = | ||
| 79 | |||
| 80 | Use the delivered drawings for the final mounting design. The following illustration is a planning summary and does not replace the configuration-specific drawings. | ||
| 81 | |||
| 82 | [[image:1788766589748-480.png]] | ||
| 83 | |||
| 84 | |||
| 85 | = Mechanical and Electrical Installation = | ||
| 86 | |||
| 87 | 1. Remove all remaining packaging and transport restraints, then place and secure the equipment upright according to the approved machine design and delivered drawings. | ||
| 88 | 1. Verify that the connection voltage and frequency match the system data. | ||
| 89 | 1. Inspect the mains cable and plug for damage and correct specification. Keep the rear main switch at 0 (OFF) before connecting the mains cable to the Auto-Light or supply socket. | ||
| 90 | 1. Complete the approved X1 safety and production-interface wiring. Connect X2 only for the axes included in the validated configuration. | ||
| 91 | 1. Route and secure the approved USB, Ethernet, HDMI, axis, safety, power, extraction, and fibre connections so they are protected from damage and do not obstruct cooling or service access. | ||
| 92 | 1. Inspect any installed laser-protection glass for damage and confirm that the complete host-machine safeguarding is ready for formal validation. | ||
| 93 | |||
| 94 | |||
| 95 | |||
| 96 | = Installation Completion Check = | ||
| 97 | |||
| 98 | Before the system is commissioned, confirm all of the following: | ||
| 99 | |||
| 100 | * The mechanical installation is complete, aligned, secure, and free from transport restraints. | ||
| 101 | * The electrical installation is complete and the input voltage is correct. | ||
| 102 | * The optics are free from dust and contamination; remove the focusing-objective protection cover only when final placement and inspection are complete. | ||
| 103 | * The environmental conditions, cooling airflow, and extraction comply with the approved design. | ||
| 104 | * The responsible personnel understand the applicable laser-safety requirements. | ||
| 105 | * Every required laser-safety measure has been implemented and is ready for verification by an authorised person. | ||
| 106 | |||
| 107 | (% class="box errormessage" %) | ||
| 108 | ((( | ||
| 109 | **Commissioning hold point: **Do not switch on the Auto-Light until an authorised person has checked every laser-safety precaution and confirmed compliance. Then follow the separate Commissioning and First Start-Up article; after relocation, complete the same electrical commissioning and functional-test sequence again. | ||
| 110 | ))) | ||
| 111 | |||
| 112 | |||
| 113 | |||
| 114 | = Long-Distance Transport = | ||
| 115 | |||
| 116 | Repack the Auto-Light as originally delivered, using the original carton, pallet, packing sections, straps, and transport restraints. The source manual specifically mentions a door restraint; install it when the delivered configuration includes an enclosure door. For other configurations, reinstall every original restraint supplied with that system. | ||
| 117 | |||
| 118 | (% class="box infomessage" %) | ||
| 119 | ((( | ||
| 120 | **Configuration control: **Do not assume that every Auto-Light delivery contains the same enclosure, Z-axis, extraction equipment, or accessories. Verify the actual scope of delivery, transport mass, lifting method, interfaces, and mounting drawings before handling or installation. | ||
| 121 | ))) |