1.1 | 1 | **Description**: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production. |
| 2 | |||
| 3 | (% class="box errormessage" %) | ||
| 4 | ((( | ||
| 5 | **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active. | ||
| 6 | ))) | ||
| 7 | |||
| 8 | ---- | ||
| 9 | |||
| |
1.2 | 10 | = Before You Start = |
| |
1.3 | 11 | |
| 12 | Confirm the operating area and machine are ready before switching on: | ||
| 13 | |||
| 14 | * Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation. | ||
| 15 | * The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use. | ||
| 16 | * The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed. | ||
| 17 | * The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area. | ||
| 18 | * The approved extraction system is running and suitable for the material and process. | ||
| 19 | * The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production. | ||
| 20 | |||
| 21 | (% class="box warningmessage" %) | ||
| 22 | ((( | ||
| 23 | **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault. | ||
| 24 | ))) | ||
| 25 | |||
| 26 | = Start = | ||
| 27 | |||
| 28 | 1. Confirm the host machine is in its approved safe start condition and extraction is operating. | ||
| 29 | 1. Set the main switch on the rear of the Auto-Light rack to I (ON). | ||
| 30 | 1. Turn the laser key switch on the front of the rack to I. | ||
| 31 | 1. Start the approved workstation and open AnyMarker Designer. | ||
| 32 | 1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active. | ||
| 33 | 1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle. | ||
| 34 | |||
| |
1.4 | 35 | |
| |
4.2 | 36 | |
| 37 | [[image:1788761121075-106.png]] | ||
| 38 | |||
| 39 | |||
| |
4.3 | 40 | = Prepare the Job = |
| |
4.2 | 41 | |
| |
4.3 | 42 | 1. Load the approved job and parameter set in AnyMarker Designer. |
| 43 | 1. Secure the workpiece in the validated fixture and select the required variable data. | ||
| 44 | 1. Use the Pilot function to display the marking field without production-laser emission. | ||
| 45 | 1. Move or adjust the workpiece until the projected field has the correct position and orientation. | ||
| 46 | 1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark. | ||
| 47 | 1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle. | ||
| 48 | |||
| 49 | (% class="box infomessage" %) | ||
| 50 | ((( | ||
| 51 | For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. | ||
| 52 | ))) | ||
| 53 | |||
| |
4.4 | 54 | |
| 55 | |||
| 56 | = Run = | ||
| 57 | |||
| 58 | 1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence. | ||
| 59 | 1. Start the job using the approved AnyMarker Designer or host-machine production sequence. | ||
| 60 | 1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation. | ||
| 61 | 1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended. | ||
| 62 | 1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state. | ||
| 63 | |||
| |
4.5 | 64 | |
| 65 | |||
| 66 | = Quality Check and Adjustment = | ||
| 67 | |||
| 68 | * Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects. | ||
| 69 | * For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy. | ||
| 70 | * Inspect the objective and protective glass if marking quality deteriorates. | ||
| 71 | * Change parameters only within the qualified process and verify changes on an approved sample before returning to production. | ||
| 72 | |||
| 73 | (% class="box errormessage" %) | ||
| 74 | ((( | ||
| 75 | **Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production. | ||
| 76 | ))) | ||
| 77 | |||
| 78 | |||
| 79 | |||
| |
4.6 | 80 | = Shutdown = |
| 81 | |||
| 82 | 1. Finish or stop the current job and confirm that laser emission has ended. | ||
| 83 | 1. Save any required production data and close AnyMarker Designer in accordance with the site procedure. | ||
| 84 | 1. Set the rear main switch to 0 (OFF). | ||
| 85 | 1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure. | ||
| 86 | 1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions. | ||
| 87 | 1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use. | ||
| 88 | |||
| 89 | |||
| 90 | |||
| |
4.7 | 91 | = If Something Does Not Work = |
| |
4.6 | 92 | |
| |
4.7 | 93 | (% class="table-condensed table-striped" style="width:1070px" %) |
| 94 | |(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check** | ||
| 95 | |(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults. | ||
| 96 | |(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability. | ||
| 97 | |(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set. | ||
| 98 | |(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation. | ||
| 99 | |||
| 100 | (% class="box warningmessage" %) | ||
| 101 | ((( | ||
| |
5.1 | 102 | **Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel. |
| |
4.7 | 103 | ))) |