Wiki source code of Operation (Start, Run, Shutdown)
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
1.1 | 1 | **Description**: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production. |
| 2 | |||
| 3 | (% class="box errormessage" %) | ||
| 4 | ((( | ||
| 5 | **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active. | ||
| 6 | ))) | ||
| 7 | |||
| 8 | ---- | ||
| 9 | |||
| |
1.2 | 10 | = Before You Start = |
| |
1.3 | 11 | |
| 12 | Confirm the operating area and machine are ready before switching on: | ||
| 13 | |||
| 14 | * Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation. | ||
| 15 | * The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use. | ||
| 16 | * The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed. | ||
| 17 | * The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area. | ||
| 18 | * The approved extraction system is running and suitable for the material and process. | ||
| 19 | * The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production. | ||
| 20 | |||
| 21 | (% class="box warningmessage" %) | ||
| 22 | ((( | ||
| 23 | **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault. | ||
| 24 | ))) | ||
| 25 | |||
| 26 | = Start = | ||
| 27 | |||
| 28 | 1. Confirm the host machine is in its approved safe start condition and extraction is operating. | ||
| 29 | 1. Set the main switch on the rear of the Auto-Light rack to I (ON). | ||
| 30 | 1. Turn the laser key switch on the front of the rack to I. | ||
| 31 | 1. Start the approved workstation and open AnyMarker Designer. | ||
| 32 | 1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active. | ||
| 33 | 1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle. | ||
| 34 | |||
| |
1.4 | 35 | |
| |
4.2 | 36 | |
| 37 | [[image:1788761121075-106.png]] | ||
| 38 | |||
| 39 | |||
| |
4.3 | 40 | = Prepare the Job = |
| |
4.2 | 41 | |
| |
4.3 | 42 | 1. Load the approved job and parameter set in AnyMarker Designer. |
| 43 | 1. Secure the workpiece in the validated fixture and select the required variable data. | ||
| 44 | 1. Use the Pilot function to display the marking field without production-laser emission. | ||
| 45 | 1. Move or adjust the workpiece until the projected field has the correct position and orientation. | ||
| 46 | 1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark. | ||
| 47 | 1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle. | ||
| 48 | |||
| 49 | (% class="box infomessage" %) | ||
| 50 | ((( | ||
| 51 | For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. | ||
| 52 | ))) | ||
| 53 | |||
| |
4.4 | 54 | |
| 55 | |||
| 56 | = Run = | ||
| 57 | |||
| 58 | 1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence. | ||
| 59 | 1. Start the job using the approved AnyMarker Designer or host-machine production sequence. | ||
| 60 | 1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation. | ||
| 61 | 1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended. | ||
| 62 | 1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state. | ||
| 63 | |||
| |
1.3 | 64 |