Operation (Start, Run, Shutdown)

Version 2.1 by jadomatis on 2026/09/07 08:10

Description: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production.

Class 4 integration laser: The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active.


Before You Start

Confirm the operating area and machine are ready before switching on:

  • Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation.
  • The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use.
  • The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed.
  • The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area.
  • The approved extraction system is running and suitable for the material and process.
  • The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production.

Do not start: Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault. 

Start

  1. Confirm the host machine is in its approved safe start condition and extraction is operating.
  2. Set the main switch on the rear of the Auto-Light rack to I (ON).
  3. Turn the laser key switch on the front of the rack to I.
  4. Start the approved workstation and open AnyMarker Designer.
  5. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active.
  6. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle.