Last modified by jadomatis on 2026/09/07 09:02

From version 6.1
edited by jadomatis
on 2026/09/07 09:02
Change comment: There is no comment for this version
To version 4.5
edited by jadomatis
on 2026/09/07 08:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 1  **Description**: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production.
2 2  
3 -{{toc/}}
4 -
5 5  (% class="box errormessage" %)
6 6  (((
7 7  **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active.
... ... @@ -25,8 +25,6 @@
25 25  **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault.
26 26  )))
27 27  
28 -= =
29 -
30 30  = Start =
31 31  
32 32  1. Confirm the host machine is in its approved safe start condition and extraction is operating.
... ... @@ -81,27 +81,4 @@
81 81  
82 82  
83 83  
84 -= Shutdown =
85 -
86 -1. Finish or stop the current job and confirm that laser emission has ended.
87 -1. Save any required production data and close AnyMarker Designer in accordance with the site procedure.
88 -1. Set the rear main switch to 0 (OFF).
89 -1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.
90 -1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions.
91 -1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use.
92 -
93 -
94 -
95 -= If Something Does Not Work =
96 -
97 -(% class="table-condensed table-striped" style="width:1070px" %)
98 -|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check**
99 -|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults.
100 -|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability.
101 -|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set.
102 -|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation.
103 -
104 -(% class="box warningmessage" %)
105 -(((
106 -**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel.
107 -)))