Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/07 09:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,5 @@ 1 1 **Description**: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production. 2 2 3 -{{toc/}} 4 - 5 5 (% class="box errormessage" %) 6 6 ((( 7 7 **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active. ... ... @@ -25,8 +25,6 @@ 25 25 **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault. 26 26 ))) 27 27 28 -= = 29 - 30 30 = Start = 31 31 32 32 1. Confirm the host machine is in its approved safe start condition and extraction is operating. ... ... @@ -36,72 +36,6 @@ 36 36 1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active. 37 37 1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle. 38 38 35 +[[image:1788761053897-133.png]] 39 39 40 - 41 -[[image:1788761121075-106.png]] 42 - 43 - 44 -= Prepare the Job = 45 - 46 -1. Load the approved job and parameter set in AnyMarker Designer. 47 -1. Secure the workpiece in the validated fixture and select the required variable data. 48 -1. Use the Pilot function to display the marking field without production-laser emission. 49 -1. Move or adjust the workpiece until the projected field has the correct position and orientation. 50 -1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark. 51 -1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle. 52 - 53 -(% class="box infomessage" %) 54 -((( 55 -For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 56 -))) 57 - 58 - 59 - 60 -= Run = 61 - 62 -1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence. 63 -1. Start the job using the approved AnyMarker Designer or host-machine production sequence. 64 -1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation. 65 -1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended. 66 -1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state. 67 - 68 - 69 - 70 -= Quality Check and Adjustment = 71 - 72 -* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects. 73 -* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy. 74 -* Inspect the objective and protective glass if marking quality deteriorates. 75 -* Change parameters only within the qualified process and verify changes on an approved sample before returning to production. 76 - 77 -(% class="box errormessage" %) 78 -((( 79 -**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production. 80 -))) 81 - 82 - 83 - 84 -= Shutdown = 85 - 86 -1. Finish or stop the current job and confirm that laser emission has ended. 87 -1. Save any required production data and close AnyMarker Designer in accordance with the site procedure. 88 -1. Set the rear main switch to 0 (OFF). 89 -1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure. 90 -1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions. 91 -1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use. 92 - 93 - 94 - 95 -= If Something Does Not Work = 96 - 97 -(% class="table-condensed table-striped" style="width:1070px" %) 98 -|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check** 99 -|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults. 100 -|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability. 101 -|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set. 102 -|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation. 103 - 104 -(% class="box warningmessage" %) 105 -((( 106 -**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel. 107 -))) 37 +
- 1788761121075-106.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -330.0 KB - Content