... ... @@ -61,43 +61,4 @@
61 61  1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended.
62 62  1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state.
63 63  
64 -
65 -
66 -= Quality Check and Adjustment =
67 -
68 -* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects.
69 -* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy.
70 -* Inspect the objective and protective glass if marking quality deteriorates.
71 -* Change parameters only within the qualified process and verify changes on an approved sample before returning to production.
72 -
73 -(% class="box errormessage" %)
74 -(((
75 -**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production.
76 -)))
77 -
78 -
79 -
80 -= Shutdown =
81 -
82 -1. Finish or stop the current job and confirm that laser emission has ended.
83 -1. Save any required production data and close AnyMarker Designer in accordance with the site procedure.
84 -1. Set the rear main switch to 0 (OFF).
85 -1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.
86 -1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions.
87 -1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use.
88 -
89 -
90 -
91 -= If Something Does Not Work =
92 -
93 -(% class="table-condensed table-striped" style="width:1070px" %)
94 -|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check**
95 -|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults.
96 -|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability.
97 -|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set.
98 -|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation.
99 -
100 -(% class="box warningmessage" %)
101 -(((
102 -**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel.