Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/07 09:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -34,70 +34,4 @@ 34 34 35 35 36 36 37 -[[image:1788761121075-106.png]] 38 - 39 - 40 -= Prepare the Job = 41 - 42 -1. Load the approved job and parameter set in AnyMarker Designer. 43 -1. Secure the workpiece in the validated fixture and select the required variable data. 44 -1. Use the Pilot function to display the marking field without production-laser emission. 45 -1. Move or adjust the workpiece until the projected field has the correct position and orientation. 46 -1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark. 47 -1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle. 48 - 49 -(% class="box infomessage" %) 50 -((( 51 -For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 52 -))) 53 - 54 - 55 - 56 -= Run = 57 - 58 -1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence. 59 -1. Start the job using the approved AnyMarker Designer or host-machine production sequence. 60 -1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation. 61 -1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended. 62 -1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state. 63 - 64 - 65 - 66 -= Quality Check and Adjustment = 67 - 68 -* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects. 69 -* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy. 70 -* Inspect the objective and protective glass if marking quality deteriorates. 71 -* Change parameters only within the qualified process and verify changes on an approved sample before returning to production. 72 - 73 -(% class="box errormessage" %) 74 -((( 75 -**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production. 76 -))) 77 - 78 - 79 - 80 -= Shutdown = 81 - 82 -1. Finish or stop the current job and confirm that laser emission has ended. 83 -1. Save any required production data and close AnyMarker Designer in accordance with the site procedure. 84 -1. Set the rear main switch to 0 (OFF). 85 -1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure. 86 -1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions. 87 -1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use. 88 - 89 - 90 - 91 -= If Something Does Not Work = 92 - 93 -(% class="table-condensed table-striped" style="width:1070px" %) 94 -|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check** 95 -|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults. 96 -|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability. 97 -|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set. 98 -|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation. 99 - 100 -(% class="box warningmessage" %) 101 -((( 102 -**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel 103 -))) 37 +
- 1788760986375-983.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -240.6 KB - Content
- 1788761053897-133.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -97.8 KB - Content
- 1788761121075-106.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -330.0 KB - Content