... ... @@ -1,5 +1,7 @@
1 1  **Description**: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production.
2 2  
3 +{{toc/}}
4 +
3 3  (% class="box errormessage" %)
4 4  (((
5 5  **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active.
... ... @@ -23,6 +23,8 @@
23 23  **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault.
24 24  )))
25 25  
28 += =
29 +
26 26  = Start =
27 27  
28 28  1. Confirm the host machine is in its approved safe start condition and extraction is operating.
... ... @@ -88,5 +88,16 @@
88 88  
89 89  
90 90  
95 += If Something Does Not Work =
91 91  
92 -
97 +(% class="table-condensed table-striped" style="width:1070px" %)
98 +|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check**
99 +|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults.
100 +|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability.
101 +|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set.
102 +|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation.
103 +
104 +(% class="box warningmessage" %)
105 +(((
106 +**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel.
107 +)))