Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/07 09:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -88,5 +88,16 @@ 88 88 89 89 90 90 91 += If Something Does Not Work = 91 91 92 - 93 +(% class="table-condensed table-striped" style="width:1070px" %) 94 +|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check** 95 +|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults. 96 +|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability. 97 +|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set. 98 +|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation. 99 + 100 +(% class="box warningmessage" %) 101 +((( 102 +**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel 103 +)))