80 -= Shutdown =
81 -
82 -1. Finish or stop the current job and confirm that laser emission has ended.
83 -1. Save any required production data and close AnyMarker Designer in accordance with the site procedure.
84 -1. Set the rear main switch to 0 (OFF).
85 -1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.
86 -1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions.
87 -1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use.
88 -
89 -