Last modified by jadomatis on 2026/09/07 09:02

From version 4.5
edited by jadomatis
on 2026/09/07 08:37
Change comment: There is no comment for this version
To version 4.3
edited by jadomatis
on 2026/09/07 08:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -51,30 +51,4 @@
51 51  For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
52 52  )))
53 53  
54 -
55 -
56 -= Run =
57 -
58 -1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence.
59 -1. Start the job using the approved AnyMarker Designer or host-machine production sequence.
60 -1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation.
61 -1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended.
62 -1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state.
63 -
64 -
65 -
66 -= Quality Check and Adjustment =
67 -
68 -* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects.
69 -* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy.
70 -* Inspect the objective and protective glass if marking quality deteriorates.
71 -* Change parameters only within the qualified process and verify changes on an approved sample before returning to production.
72 -
73 -(% class="box errormessage" %)
74 -(((
75 -**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production.
76 -)))
77 -
78 -
79 -
80 80