Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/07 09:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,74 +7,4 @@ 7 7 8 8 ---- 9 9 10 -= Before You Start = 11 - 12 -Confirm the operating area and machine are ready before switching on: 13 - 14 -* Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation. 15 -* The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use. 16 -* The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed. 17 -* The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area. 18 -* The approved extraction system is running and suitable for the material and process. 19 -* The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production. 20 - 21 -(% class="box warningmessage" %) 22 -((( 23 -**Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault. 24 -))) 25 - 26 -= Start = 27 - 28 -1. Confirm the host machine is in its approved safe start condition and extraction is operating. 29 -1. Set the main switch on the rear of the Auto-Light rack to I (ON). 30 -1. Turn the laser key switch on the front of the rack to I. 31 -1. Start the approved workstation and open AnyMarker Designer. 32 -1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active. 33 -1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle. 34 - 35 - 36 - 37 -[[image:1788761121075-106.png]] 38 - 39 - 40 -= Prepare the Job = 41 - 42 -1. Load the approved job and parameter set in AnyMarker Designer. 43 -1. Secure the workpiece in the validated fixture and select the required variable data. 44 -1. Use the Pilot function to display the marking field without production-laser emission. 45 -1. Move or adjust the workpiece until the projected field has the correct position and orientation. 46 -1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark. 47 -1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle. 48 - 49 -(% class="box infomessage" %) 50 -((( 51 -For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 52 -))) 53 - 54 - 55 - 56 -= Run = 57 - 58 -1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence. 59 -1. Start the job using the approved AnyMarker Designer or host-machine production sequence. 60 -1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation. 61 -1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended. 62 -1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state. 63 - 64 - 65 - 66 -= Quality Check and Adjustment = 67 - 68 -* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects. 69 -* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy. 70 -* Inspect the objective and protective glass if marking quality deteriorates. 71 -* Change parameters only within the qualified process and verify changes on an approved sample before returning to production. 72 - 73 -(% class="box errormessage" %) 74 -((( 75 -**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production. 76 -))) 77 - 78 - 79 - 80 - 10 += =
- 1788760986375-983.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -240.6 KB - Content
- 1788761053897-133.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -97.8 KB - Content
- 1788761121075-106.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -330.0 KB - Content