Last modified by jadomatis on 2026/09/07 09:02

From version 4.3
edited by jadomatis
on 2026/09/07 08:16
Change comment: There is no comment for this version
To version 1.2
edited by jadomatis
on 2026/09/07 07:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,47 +8,3 @@
8 8  ----
9 9  
10 10  = Before You Start =
11 -
12 -Confirm the operating area and machine are ready before switching on:
13 -
14 -* Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation.
15 -* The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use.
16 -* The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed.
17 -* The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area.
18 -* The approved extraction system is running and suitable for the material and process.
19 -* The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production.
20 -
21 -(% class="box warningmessage" %)
22 -(((
23 -**Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault.
24 -)))
25 -
26 -= Start =
27 -
28 -1. Confirm the host machine is in its approved safe start condition and extraction is operating.
29 -1. Set the main switch on the rear of the Auto-Light rack to I (ON).
30 -1. Turn the laser key switch on the front of the rack to I.
31 -1. Start the approved workstation and open AnyMarker Designer.
32 -1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active.
33 -1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle.
34 -
35 -
36 -
37 -[[image:1788761121075-106.png]]
38 -
39 -
40 -= Prepare the Job =
41 -
42 -1. Load the approved job and parameter set in AnyMarker Designer.
43 -1. Secure the workpiece in the validated fixture and select the required variable data.
44 -1. Use the Pilot function to display the marking field without production-laser emission.
45 -1. Move or adjust the workpiece until the projected field has the correct position and orientation.
46 -1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark.
47 -1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle.
48 -
49 -(% class="box infomessage" %)
50 -(((
51 -For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
52 -)))
53 -
54 -
1788760986375-983.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -240.6 KB
Content
1788761053897-133.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -97.8 KB
Content
1788761121075-106.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -330.0 KB
Content