10 10  = Before You Start =
11 -
12 -Confirm the operating area and machine are ready before switching on:
13 -
14 -* Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation.
15 -* The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use.
16 -* The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed.
17 -* The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area.
18 -* The approved extraction system is running and suitable for the material and process.
19 -* The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production.
20 -
21 -(% class="box warningmessage" %)
22 -(((
23 -**Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault.
24 -)))
25 -
26 -= Start =
27 -
28 -1. Confirm the host machine is in its approved safe start condition and extraction is operating.
29 -1. Set the main switch on the rear of the Auto-Light rack to I (ON).
30 -1. Turn the laser key switch on the front of the rack to I.
31 -1. Start the approved workstation and open AnyMarker Designer.
32 -1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active.
33 -1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle.
34 -
35 -[[image:1788761053897-133.png]]
36 -
37 -
1788760986375-983.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -240.6 KB
Content
1788761053897-133.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -97.8 KB
Content