... ... @@ -34,4 +34,47 @@
34 34  
35 35  
36 36  
37 +[[image:1788761121075-106.png]]
38 +
39 +
40 += Prepare the Job =
41 +
42 +1. Load the approved job and parameter set in AnyMarker Designer.
43 +1. Secure the workpiece in the validated fixture and select the required variable data.
44 +1. Use the Pilot function to display the marking field without production-laser emission.
45 +1. Move or adjust the workpiece until the projected field has the correct position and orientation.
46 +1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark.
47 +1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle.
48 +
49 +(% class="box infomessage" %)
50 +(((
51 +For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
52 +)))
53 +
54 +
55 +
56 += Run =
57 +
58 +1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence.
59 +1. Start the job using the approved AnyMarker Designer or host-machine production sequence.
60 +1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation.
61 +1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended.
62 +1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state.
63 +
64 +
65 +
66 += Quality Check and Adjustment =
67 +
68 +* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects.
69 +* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy.
70 +* Inspect the objective and protective glass if marking quality deteriorates.
71 +* Change parameters only within the qualified process and verify changes on an approved sample before returning to production.
72 +
73 +(% class="box errormessage" %)
74 +(((
75 +**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production.
76 +)))
77 +
78 +
79 +