Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/07 09:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,7 @@ 1 1 **Description**: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production. 2 2 3 +{{toc/}} 4 + 3 3 (% class="box errormessage" %) 4 4 ((( 5 5 **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active. ... ... @@ -23,6 +23,8 @@ 23 23 **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault. 24 24 ))) 25 25 28 += = 29 + 26 26 = Start = 27 27 28 28 1. Confirm the host machine is in its approved safe start condition and extraction is operating. ... ... @@ -34,4 +34,70 @@ 34 34 35 35 36 36 37 - 41 +[[image:1788761121075-106.png]] 42 + 43 + 44 += Prepare the Job = 45 + 46 +1. Load the approved job and parameter set in AnyMarker Designer. 47 +1. Secure the workpiece in the validated fixture and select the required variable data. 48 +1. Use the Pilot function to display the marking field without production-laser emission. 49 +1. Move or adjust the workpiece until the projected field has the correct position and orientation. 50 +1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark. 51 +1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle. 52 + 53 +(% class="box infomessage" %) 54 +((( 55 +For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 56 +))) 57 + 58 + 59 + 60 += Run = 61 + 62 +1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence. 63 +1. Start the job using the approved AnyMarker Designer or host-machine production sequence. 64 +1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation. 65 +1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended. 66 +1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state. 67 + 68 + 69 + 70 += Quality Check and Adjustment = 71 + 72 +* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects. 73 +* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy. 74 +* Inspect the objective and protective glass if marking quality deteriorates. 75 +* Change parameters only within the qualified process and verify changes on an approved sample before returning to production. 76 + 77 +(% class="box errormessage" %) 78 +((( 79 +**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production. 80 +))) 81 + 82 + 83 + 84 += Shutdown = 85 + 86 +1. Finish or stop the current job and confirm that laser emission has ended. 87 +1. Save any required production data and close AnyMarker Designer in accordance with the site procedure. 88 +1. Set the rear main switch to 0 (OFF). 89 +1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure. 90 +1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions. 91 +1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use. 92 + 93 + 94 + 95 += If Something Does Not Work = 96 + 97 +(% class="table-condensed table-striped" style="width:1070px" %) 98 +|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check** 99 +|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults. 100 +|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability. 101 +|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set. 102 +|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation. 103 + 104 +(% class="box warningmessage" %) 105 +((( 106 +**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel. 107 +)))
- 1788761053897-133.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +97.8 KB - Content
- 1788761121075-106.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +330.0 KB - Content