... ... @@ -34,4 +34,70 @@
34 34  
35 35  
36 36  
37 -
37 +[[image:1788761121075-106.png]]
38 +
39 +
40 += Prepare the Job =
41 +
42 +1. Load the approved job and parameter set in AnyMarker Designer.
43 +1. Secure the workpiece in the validated fixture and select the required variable data.
44 +1. Use the Pilot function to display the marking field without production-laser emission.
45 +1. Move or adjust the workpiece until the projected field has the correct position and orientation.
46 +1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark.
47 +1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle.
48 +
49 +(% class="box infomessage" %)
50 +(((
51 +For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
52 +)))
53 +
54 +
55 +
56 += Run =
57 +
58 +1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence.
59 +1. Start the job using the approved AnyMarker Designer or host-machine production sequence.
60 +1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation.
61 +1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended.
62 +1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state.
63 +
64 +
65 +
66 += Quality Check and Adjustment =
67 +
68 +* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects.
69 +* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy.
70 +* Inspect the objective and protective glass if marking quality deteriorates.
71 +* Change parameters only within the qualified process and verify changes on an approved sample before returning to production.
72 +
73 +(% class="box errormessage" %)
74 +(((
75 +**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production.
76 +)))
77 +
78 +
79 +
80 += Shutdown =
81 +
82 +1. Finish or stop the current job and confirm that laser emission has ended.
83 +1. Save any required production data and close AnyMarker Designer in accordance with the site procedure.
84 +1. Set the rear main switch to 0 (OFF).
85 +1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.
86 +1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions.
87 +1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use.
88 +
89 +
90 +
91 += If Something Does Not Work =
92 +
93 +(% class="table-condensed table-striped" style="width:1070px" %)
94 +|(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check**
95 +|(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults.
96 +|(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability.
97 +|(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set.
98 +|(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation.
99 +
100 +(% class="box warningmessage" %)
101 +(((
102 +**Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel
103 +)))
1788760986375-983.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +240.6 KB
Content
1788761053897-133.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +97.8 KB
Content
1788761121075-106.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +330.0 KB
Content