Last modified by jadomatis on 2026/09/07 09:02

From version 1.1
edited by jadomatis
on 2026/09/07 07:53
Change comment: There is no comment for this version
To version 4.5
edited by jadomatis
on 2026/09/07 08:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -7,4 +7,74 @@
7 7  
8 8  ----
9 9  
10 -= =
10 += Before You Start =
11 +
12 +Confirm the operating area and machine are ready before switching on:
13 +
14 +* Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation.
15 +* The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use.
16 +* The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed.
17 +* The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area.
18 +* The approved extraction system is running and suitable for the material and process.
19 +* The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production.
20 +
21 +(% class="box warningmessage" %)
22 +(((
23 +**Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault.
24 +)))
25 +
26 += Start =
27 +
28 +1. Confirm the host machine is in its approved safe start condition and extraction is operating.
29 +1. Set the main switch on the rear of the Auto-Light rack to I (ON).
30 +1. Turn the laser key switch on the front of the rack to I.
31 +1. Start the approved workstation and open AnyMarker Designer.
32 +1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active.
33 +1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle.
34 +
35 +
36 +
37 +[[image:1788761121075-106.png]]
38 +
39 +
40 += Prepare the Job =
41 +
42 +1. Load the approved job and parameter set in AnyMarker Designer.
43 +1. Secure the workpiece in the validated fixture and select the required variable data.
44 +1. Use the Pilot function to display the marking field without production-laser emission.
45 +1. Move or adjust the workpiece until the projected field has the correct position and orientation.
46 +1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark.
47 +1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle.
48 +
49 +(% class="box infomessage" %)
50 +(((
51 +For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
52 +)))
53 +
54 +
55 +
56 += Run =
57 +
58 +1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence.
59 +1. Start the job using the approved AnyMarker Designer or host-machine production sequence.
60 +1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation.
61 +1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended.
62 +1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state.
63 +
64 +
65 +
66 += Quality Check and Adjustment =
67 +
68 +* Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects.
69 +* For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy.
70 +* Inspect the objective and protective glass if marking quality deteriorates.
71 +* Change parameters only within the qualified process and verify changes on an approved sample before returning to production.
72 +
73 +(% class="box errormessage" %)
74 +(((
75 +**Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production.
76 +)))
77 +
78 +
79 +
80 +
1788760986375-983.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +240.6 KB
Content
1788761053897-133.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +97.8 KB
Content
1788761121075-106.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +330.0 KB
Content