7 **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active.
8 )))
9
10 ----
11
jadomatis 1.2 12 = Before You Start =
jadomatis 1.3 13
14 Confirm the operating area and machine are ready before switching on:
15
16 * Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation.
17 * The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use.
18 * The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed.
19 * The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area.
20 * The approved extraction system is running and suitable for the material and process.
21 * The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production.
22
23 (% class="box warningmessage" %)
24 (((
25 **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault.
26 )))
27
jadomatis 6.1 28 = =
29
jadomatis 1.3 30 = Start =
31
32 1. Confirm the host machine is in its approved safe start condition and extraction is operating.
33 1. Set the main switch on the rear of the Auto-Light rack to I (ON).
34 1. Turn the laser key switch on the front of the rack to I.
35 1. Start the approved workstation and open AnyMarker Designer.
36 1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active.
37 1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle.
38
jadomatis 1.4 39
jadomatis 4.2 40
41 [[image:1788761121075-106.png]]
42
43
jadomatis 4.3 44 = Prepare the Job =
jadomatis 4.2 45
jadomatis 4.3 46 1. Load the approved job and parameter set in AnyMarker Designer.
47 1. Secure the workpiece in the validated fixture and select the required variable data.
48 1. Use the Pilot function to display the marking field without production-laser emission.
49 1. Move or adjust the workpiece until the projected field has the correct position and orientation.
50 1. Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark.
51 1. Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle.
52
53 (% class="box infomessage" %)
54 (((
55 For software-specific job preparation, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
56 )))
57
jadomatis 4.4 58
59
60 = Run =
61
62 1. Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence.
63 1. Start the job using the approved AnyMarker Designer or host-machine production sequence.
64 1. Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation.
65 1. Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended.
66 1. If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state.
67
jadomatis 4.5 68
69
70 = Quality Check and Adjustment =
71
72 * Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects.
73 * For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy.
74 * Inspect the objective and protective glass if marking quality deteriorates.
75 * Change parameters only within the qualified process and verify changes on an approved sample before returning to production.
76
77 (% class="box errormessage" %)
78 (((
79 **Stop immediately: **Stop the job if there is unexpected motion, smoke, fire, abnormal noise, a safety fault, loss of extraction, or any other behaviour outside the validated process. Do not bypass the cause to continue production.
80 )))
81
82
83
jadomatis 4.6 84 = Shutdown =
85
86 1. Finish or stop the current job and confirm that laser emission has ended.
87 1. Save any required production data and close AnyMarker Designer in accordance with the site procedure.
88 1. Set the rear main switch to 0 (OFF).
89 1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.
90 1. Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions.
91 1. Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use.
92
93
94
jadomatis 4.7 95 = If Something Does Not Work =
jadomatis 4.6 96
jadomatis 4.7 97 (% class="table-condensed table-striped" style="width:1070px" %)
98 |(% style="width:309px" %)**Symptom**|(% style="width:760px" %)**Check**
99 |(% style="width:309px" %)No ready signal|(% style="width:760px" %)Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults.
100 |(% style="width:309px" %)No marking|(% style="width:760px" %)Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability.
101 |(% style="width:309px" %)Weak marking|(% style="width:760px" %)Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set.
102 |(% style="width:309px" %)Unexpected stop|(% style="width:760px" %)Treat the loss of a start condition as a fault. Secure and isolate the system before investigation.
103
104 (% class="box warningmessage" %)
105 (((
jadomatis 5.1 106 **Unresolved fault: **Switch off the system and contact Schilling Service or authorised maintenance personnel. Repairs must not be attempted by unqualified personnel.