Version 1.4 by jadomatis on 2026/09/07 08:10

Show last authors
1 **Description**: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production.
2
3 (% class="box errormessage" %)
4 (((
5 **Class 4 integration laser: **The Auto-Light does not provide a complete protective enclosure. Operate it only through the approved host machine, with the enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all other integration-safety functions active.
6 )))
7
8 ----
9
10 = Before You Start =
11
12 Confirm the operating area and machine are ready before switching on:
13
14 * Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation.
15 * The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use.
16 * The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed.
17 * The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area.
18 * The approved extraction system is running and suitable for the material and process.
19 * The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production.
20
21 (% class="box warningmessage" %)
22 (((
23 **Do not start: **Never bypass a guard, emergency-stop circuit, shutter circuit, acknowledgement, or other safety function. If a safety device is missing, damaged, or does not behave as validated, keep the system switched off and report the fault.
24 )))
25
26 = Start =
27
28 1. Confirm the host machine is in its approved safe start condition and extraction is operating.
29 1. Set the main switch on the rear of the Auto-Light rack to I (ON).
30 1. Turn the laser key switch on the front of the rack to I.
31 1. Start the approved workstation and open AnyMarker Designer.
32 1. Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active.
33 1. Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle.
34
35