Wiki-Quellcode von Maintenance WIP

Version 5.7 von jadomatis am 2026/09/07 07:20

Verstecke letzte Bearbeiter
jadomatis 2.1 1 **Description**: Learn how to maintain the Auto-Light optics, cooling airflow, filters and extraction systems to preserve safe operation and consistent marking quality.
jadomatis 3.2 2
3 (% class="box warningmessage" %)
4 (((
5 **CAUTION: **Before maintenance, switch off and fully de-energise the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorised personnel.
6 )))
7
8 = Responsibilities and Original Parts =
9
10 1. Use original spare parts and approved consumables. Incompatible parts can impair safety and equipment reliability.
11 1. Do not remove, bypass, or modify safety-related components, the shutter, the laser head, or protective covers.
12 1. Reinstall every cover, connection, warning label, and safety device before returning the integrated machine to service.
13 1. Do not use flammable or explosive cleaning agents in the processing area.
jadomatis 4.2 14
jadomatis 5.3 15
16
jadomatis 4.2 17 = Daily Visual Check =
18
19 1. Inspect the lens and objective protective glass; clean only when necessary.
20 1. Check the laser head, fibre routing, connectors, and rack for visible damage.
21 1. Confirm that warning and identification labels are present and legible.
22 1. Keep the work area clean and verify that process-fume extraction is available.
23 1. Ensure the front and rear cooling openings are unobstructed.
24
25
26
27 = Airflow, Filters, and Work Environment =
28
29 The Auto-Light is air-cooled. Filter mats protect the rack electronics from dust and contamination. Blocked openings or contaminated filter mats cause heat accumulation and can damage the system.
30
jadomatis 5.2 31 [[**Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.**>>image:1788756663547-478.png||height="275" width="589"]]
jadomatis 4.2 32
jadomatis 4.3 33
34 1. Inspect the filter mats behind the front and rear ventilation openings and replace them when contaminated.
35 1. Keep the surrounding area clean to reduce dust entering the cooling system and settling on optics.
36 1. Operate suitable extraction whenever marking produces gases, vapors, aerosols, or dust.
37
38
39
40 = Cleaning Optical Components =
41
42 Laser optics are easily damaged. Prevent contamination through effective extraction and a clean work area. Never touch optical surfaces with bare fingers.
43
44 1. Isolate the system and prepare a clean work area.
45 1. Remove loose dust with a small clean hand blower. Do not use workshop compressed air because it can contain oil or water.
46 1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container.
47 1. Wipe gently in a circular motion from the centre toward the edge. Keep the tissue moving and do not apply pressure.
48 1. Do not use tools or hard objects. Scratches cannot be repaired.
jadomatis 5.2 49 1. If contamination cannot be removed safely, stop and contact service
50
jadomatis 5.3 51
52
jadomatis 5.2 53 [[**Example F-Theta lens. Handle optical surfaces only with approved methods and materials.**>>image:1788757524363-116.png]]
54
jadomatis 5.3 55
jadomatis 5.2 56 = Suggested Maintenance Intervals =
jadomatis 5.3 57
58 (% class="table-condensed table-striped" %)
jadomatis 5.5 59 |=(% style="width: 234px;" %)**Interval**|=(% style="width: 262px;" %)**Item**|=(% style="width: 712px;" %)**Method**
60 |(% style="width:234px" %)Daily|(% style="width:262px" %)Lens|(% style="width:712px" %)Inspect and clean if necessary.
61 |(% style="width:234px" %)Monthly|(% style="width:262px" %)Objective protective glass|(% style="width:712px" %)Wipe carefully with a soft cloth and approved optical-cleaning agent. The source mentions acetone or diethyl ether; follow the chemical safety data and site rules.
62 |(% style="width:234px" %)Monthly|(% style="width:262px" %)Fan and ventilation area|(% style="width:712px" %)Wipe carefully with a dry cloth. Replace heavily contaminated filter mats.
63 |(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction pre-filter, if fitted|(% style="width:712px" %)Inspect and replace when full.
64 |(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction main filter, if fitted|(% style="width:712px" %)Inspect and replace when contaminated; shorten the interval for high process loads.
jadomatis 5.3 65
jadomatis 5.5 66 (% class="box infomessage" %)
67 (((
jadomatis 5.6 68 Intervals are suggestions for default working environment. Increase inspection frequency for dusty environments or high utilization
jadomatis 5.5 69 )))
jadomatis 5.7 70