Änderungen von Dokument Maintenance

Zuletzt geändert von jadomatis am 2026/09/07 09:01

Von Version 6.1
bearbeitet von jadomatis
am 2026/09/07 07:31
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 5.8
bearbeitet von jadomatis
am 2026/09/07 07:30
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -2,7 +2,7 @@
2 2  
3 3  (% class="box warningmessage" %)
4 4  (((
5 -**CAUTION: **Before maintenance, switch off and fully de-energize the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorized personnel.
5 +**CAUTION: **Before maintenance, switch off and fully de-energise the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorized personnel.
6 6  )))
7 7  
8 8  = Responsibilities and Original Parts =
... ... @@ -17,7 +17,7 @@
17 17  = Daily Visual Check =
18 18  
19 19  1. Inspect the lens and objective protective glass; clean only when necessary.
20 -1. Check the laser head, fiber routing, connectors, and rack for visible damage.
20 +1. Check the laser head, fibre routing, connectors, and rack for visible damage.
21 21  1. Confirm that warning and identification labels are present and legible.
22 22  1. Keep the work area clean and verify that process-fume extraction is available.
23 23  1. Ensure the front and rear cooling openings are unobstructed.
... ... @@ -44,7 +44,7 @@
44 44  1. Isolate the system and prepare a clean work area.
45 45  1. Remove loose dust with a small clean hand blower. Do not use workshop compressed air because it can contain oil or water.
46 46  1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container.
47 -1. Wipe gently in a circular motion from the center toward the edge. Keep the tissue moving and do not apply pressure.
47 +1. Wipe gently in a circular motion from the centre toward the edge. Keep the tissue moving and do not apply pressure.
48 48  1. Do not use tools or hard objects. Scratches cannot be repaired.
49 49  1. If contamination cannot be removed safely, stop and contact service
50 50