Changes for page Maintenance

Last modified by jadomatis on 2026/09/07 09:01

From version 5.6
edited by jadomatis
on 2026/09/07 07:19
Change comment: There is no comment for this version
To version 5.1
edited by jadomatis
on 2026/09/07 07:12
Change comment: Uploaded new attachment "1788757524363-116.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -12,8 +12,6 @@
12 12  1. Reinstall every cover, connection, warning label, and safety device before returning the integrated machine to service.
13 13  1. Do not use flammable or explosive cleaning agents in the processing area.
14 14  
15 -
16 -
17 17  = Daily Visual Check =
18 18  
19 19  1. Inspect the lens and objective protective glass; clean only when necessary.
... ... @@ -28,7 +28,7 @@
28 28  
29 29  The Auto-Light is air-cooled. Filter mats protect the rack electronics from dust and contamination. Blocked openings or contaminated filter mats cause heat accumulation and can damage the system.
30 30  
31 -[[**Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.**>>image:1788756663547-478.png||height="275" width="589"]]
29 +[[//Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.//>>image:1788756663547-478.png||height="275" width="589"]]
32 32  
33 33  
34 34  1. Inspect the filter mats behind the front and rear ventilation openings and replace them when contaminated.
... ... @@ -46,24 +46,4 @@
46 46  1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container.
47 47  1. Wipe gently in a circular motion from the centre toward the edge. Keep the tissue moving and do not apply pressure.
48 48  1. Do not use tools or hard objects. Scratches cannot be repaired.
49 -1. If contamination cannot be removed safely, stop and contact service
50 -
51 -
52 -
53 -[[**Example F-Theta lens. Handle optical surfaces only with approved methods and materials.**>>image:1788757524363-116.png]]
54 -
55 -
56 -= Suggested Maintenance Intervals =
57 -
58 -(% class="table-condensed table-striped" %)
59 -|=(% style="width: 234px;" %)**Interval**|=(% style="width: 262px;" %)**Item**|=(% style="width: 712px;" %)**Method**
60 -|(% style="width:234px" %)Daily|(% style="width:262px" %)Lens|(% style="width:712px" %)Inspect and clean if necessary.
61 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Objective protective glass|(% style="width:712px" %)Wipe carefully with a soft cloth and approved optical-cleaning agent. The source mentions acetone or diethyl ether; follow the chemical safety data and site rules.
62 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Fan and ventilation area|(% style="width:712px" %)Wipe carefully with a dry cloth. Replace heavily contaminated filter mats.
63 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction pre-filter, if fitted|(% style="width:712px" %)Inspect and replace when full.
64 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction main filter, if fitted|(% style="width:712px" %)Inspect and replace when contaminated; shorten the interval for high process loads.
65 -
66 -(% class="box infomessage" %)
67 -(((
68 -Intervals are suggestions for default working environment. Increase inspection frequency for dusty environments or high utilization
69 -)))
47 +1. If contamination cannot be removed safely, stop and contact service.