1 1  **Description**: Learn how to maintain the Auto-Light optics, cooling airflow, filters and extraction systems to preserve safe operation and consistent marking quality.
2 -
3 -(% class="box warningmessage" %)
4 -(((
5 -**CAUTION: **Before maintenance, switch off and fully de-energise the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorised personnel.
6 -)))
7 -
8 -= Responsibilities and Original Parts =
9 -
10 -1. Use original spare parts and approved consumables. Incompatible parts can impair safety and equipment reliability.
11 -1. Do not remove, bypass, or modify safety-related components, the shutter, the laser head, or protective covers.
12 -1. Reinstall every cover, connection, warning label, and safety device before returning the integrated machine to service.
13 -1. Do not use flammable or explosive cleaning agents in the processing area.
14 -
15 -
16 -
17 -= Daily Visual Check =
18 -
19 -1. Inspect the lens and objective protective glass; clean only when necessary.
20 -1. Check the laser head, fibre routing, connectors, and rack for visible damage.
21 -1. Confirm that warning and identification labels are present and legible.
22 -1. Keep the work area clean and verify that process-fume extraction is available.
23 -1. Ensure the front and rear cooling openings are unobstructed.
24 -
25 -
26 -
27 -= Airflow, Filters, and Work Environment =
28 -
29 -The Auto-Light is air-cooled. Filter mats protect the rack electronics from dust and contamination. Blocked openings or contaminated filter mats cause heat accumulation and can damage the system.
30 -
31 -[[**Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.**>>image:1788756663547-478.png||height="275" width="589"]]
32 -
33 -
34 -1. Inspect the filter mats behind the front and rear ventilation openings and replace them when contaminated.
35 -1. Keep the surrounding area clean to reduce dust entering the cooling system and settling on optics.
36 -1. Operate suitable extraction whenever marking produces gases, vapors, aerosols, or dust.
37 -
38 -
39 -
40 -= Cleaning Optical Components =
41 -
42 -Laser optics are easily damaged. Prevent contamination through effective extraction and a clean work area. Never touch optical surfaces with bare fingers.
43 -
44 -1. Isolate the system and prepare a clean work area.
45 -1. Remove loose dust with a small clean hand blower. Do not use workshop compressed air because it can contain oil or water.
46 -1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container.
47 -1. Wipe gently in a circular motion from the centre toward the edge. Keep the tissue moving and do not apply pressure.
48 -1. Do not use tools or hard objects. Scratches cannot be repaired.
49 -1. If contamination cannot be removed safely, stop and contact service
50 -
51 -
52 -
53 -[[**Example F-Theta lens. Handle optical surfaces only with approved methods and materials.**>>image:1788757524363-116.png]]
54 -
55 -
56 -= Suggested Maintenance Intervals =
57 -
58 -(% class="table-condensed table-striped" %)
59 -|=(% style="width: 234px;" %)**Interval**|=(% style="width: 262px;" %)**Item**|=(% style="width: 712px;" %)**Method**
60 -|(% style="width:234px" %)Daily|(% style="width:262px" %)Lens|(% style="width:712px" %)Inspect and clean if necessary.
61 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Objective protective glass|(% style="width:712px" %)Wipe carefully with a soft cloth and approved optical-cleaning agent. The source mentions acetone or diethyl ether; follow the chemical safety data and site rules.
62 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Fan and ventilation area|(% style="width:712px" %)Wipe carefully with a dry cloth. Replace heavily contaminated filter mats.
63 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction pre-filter, if fitted|(% style="width:712px" %)Inspect and replace when full.
64 -|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction main filter, if fitted|(% style="width:712px" %)Inspect and replace when contaminated; shorten the interval for high process loads.
65 -
66 -(% class="box infomessage" %)
67 -(((
68 -//Intervals reproduced from the Auto-Light manual; increase inspection frequency for dusty environments or high utilisation//