4 4  (((
5 -**CAUTION: **Before maintenance, switch off and fully de-energise the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorised personnel.
5 +**CAUTION: **Before maintenance, switch off and fully de-energise the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorized personnel.
6 6  )))
7 7  
8 8  = Responsibilities and Original Parts =
... ... @@ -56,11 +56,35 @@
56 56  = Suggested Maintenance Intervals =
57 57  
58 58  (% class="table-condensed table-striped" %)
59 -|=**Interval**|= |=
60 -| | |
61 -| | |
62 -| | |
63 -| | |
64 -| | |
59 +|=(% style="width: 234px;" %)**Interval**|=(% style="width: 262px;" %)**Item**|=(% style="width: 712px;" %)**Method**
60 +|(% style="width:234px" %)Daily|(% style="width:262px" %)Lens|(% style="width:712px" %)Inspect and clean if necessary.
61 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Objective protective glass|(% style="width:712px" %)Wipe carefully with a soft cloth and approved optical-cleaning agent. The source mentions acetone or diethyl ether; follow the chemical safety data and site rules.
62 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Fan and ventilation area|(% style="width:712px" %)Wipe carefully with a dry cloth. Replace heavily contaminated filter mats.
63 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction pre-filter, if fitted|(% style="width:712px" %)Inspect and replace when full.
64 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction main filter, if fitted|(% style="width:712px" %)Inspect and replace when contaminated; shorten the interval for high process loads.
65 65  
66 -
66 +(% class="box infomessage" %)
67 +(((
68 +Intervals are suggestions for default working environment. Increase inspection frequency for dusty environments or high utilization
69 +)))
70 +
71 +
72 +
73 += Avoiding Faults - Typical Causes and Remedies =
74 +
75 +(% class="table-condensed table-striped" %)
76 +|**Observation**|**Maintenance response**
77 +|Weak or inconsistent marking|Verify focus first; inspect the objective and protective glass for contamination; confirm the approved parameter set.
78 +|Thermal alarm or unstable operation|Check that cooling openings are clear, clean the ventilation area, inspect filter mats, and verify ambient conditions.
79 +|Deposits around the process area|Check extraction airflow and filter condition; clean surrounding surfaces and review the qualified process.
80 +|Visible optical damage|Stop operation. Do not attempt to polish scratches or continue with a cracked protective glass; contact service.
81 +
82 +
83 +
84 += After Maintenance - Return to Service =
85 +
86 +1. Confirm all covers, connectors, safeguards, and labels are installed and secure.
87 +1. Remove tools, tissues, solvents, and loose objects from the marking area.
88 +1. Restore power and verify the complete host-machine safety sequence, including emergency stop and shutter interlocks.
89 +1. Confirm cooling airflow and extraction operation.
90 +1. Perform a pilot-positioning check and a short test mark on an approved sample.