Changes for page Maintenance

Last modified by jadomatis on 2026/09/07 09:01

From version 5.3
edited by jadomatis
on 2026/09/07 07:15
Change comment: There is no comment for this version
To version 5.6
edited by jadomatis
on 2026/09/07 07:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -56,11 +56,14 @@
56 56  = Suggested Maintenance Intervals =
57 57  
58 58  (% class="table-condensed table-striped" %)
59 -|=**Interval**|= |=
60 -| | |
61 -| | |
62 -| | |
63 -| | |
64 -| | |
59 +|=(% style="width: 234px;" %)**Interval**|=(% style="width: 262px;" %)**Item**|=(% style="width: 712px;" %)**Method**
60 +|(% style="width:234px" %)Daily|(% style="width:262px" %)Lens|(% style="width:712px" %)Inspect and clean if necessary.
61 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Objective protective glass|(% style="width:712px" %)Wipe carefully with a soft cloth and approved optical-cleaning agent. The source mentions acetone or diethyl ether; follow the chemical safety data and site rules.
62 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Fan and ventilation area|(% style="width:712px" %)Wipe carefully with a dry cloth. Replace heavily contaminated filter mats.
63 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction pre-filter, if fitted|(% style="width:712px" %)Inspect and replace when full.
64 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction main filter, if fitted|(% style="width:712px" %)Inspect and replace when contaminated; shorten the interval for high process loads.
65 65  
66 -
66 +(% class="box infomessage" %)
67 +(((
68 +Intervals are suggestions for default working environment. Increase inspection frequency for dusty environments or high utilization
69 +)))