... ... @@ -1,10 +1,15 @@
1 1  **Description**: Learn how to maintain the Auto-Light optics, cooling airflow, filters and extraction systems to preserve safe operation and consistent marking quality.
2 2  
3 +{{toc/}}
4 +
5 +----
6 +
3 3  (% class="box warningmessage" %)
4 4  (((
5 -**CAUTION: **Before maintenance, switch off and fully de-energise the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorised personnel.
9 + **CAUTION: **Before maintenance, switch off and fully de-energize the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorized personnel.
6 6  )))
7 7  
12 +
8 8  = Responsibilities and Original Parts =
9 9  
10 10  1. Use original spare parts and approved consumables. Incompatible parts can impair safety and equipment reliability.
... ... @@ -12,10 +12,12 @@
12 12  1. Reinstall every cover, connection, warning label, and safety device before returning the integrated machine to service.
13 13  1. Do not use flammable or explosive cleaning agents in the processing area.
14 14  
15 -= Daily Visual Check =
16 16  
21 +
22 += Daily Visual Check =
23 +
17 17  1. Inspect the lens and objective protective glass; clean only when necessary.
18 -1. Check the laser head, fibre routing, connectors, and rack for visible damage.
25 +1. Check the laser head, fiber routing, connectors, and rack for visible damage.
19 19  1. Confirm that warning and identification labels are present and legible.
20 20  1. Keep the work area clean and verify that process-fume extraction is available.
21 21  1. Ensure the front and rear cooling openings are unobstructed.
... ... @@ -42,10 +42,48 @@
42 42  1. Isolate the system and prepare a clean work area.
43 43  1. Remove loose dust with a small clean hand blower. Do not use workshop compressed air because it can contain oil or water.
44 44  1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container.
45 -1. Wipe gently in a circular motion from the centre toward the edge. Keep the tissue moving and do not apply pressure.
52 +1. Wipe gently in a circular motion from the center toward the edge. Keep the tissue moving and do not apply pressure.
46 46  1. Do not use tools or hard objects. Scratches cannot be repaired.
47 47  1. If contamination cannot be removed safely, stop and contact service
48 48  
56 +
57 +
49 49  [[**Example F-Theta lens. Handle optical surfaces only with approved methods and materials.**>>image:1788757524363-116.png]]
50 50  
51 -= Suggested Maintenance Intervals =
60 +
61 += Suggested Maintenance Intervals =
62 +
63 +(% class="table-condensed table-striped" %)
64 +|=(% style="width: 234px;" %)**Interval**|=(% style="width: 262px;" %)**Item**|=(% style="width: 712px;" %)**Method**
65 +|(% style="width:234px" %)Daily|(% style="width:262px" %)Lens|(% style="width:712px" %)Inspect and clean if necessary.
66 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Objective protective glass|(% style="width:712px" %)Wipe carefully with a soft cloth and approved optical-cleaning agent. The source mentions acetone or diethyl ether; follow the chemical safety data and site rules.
67 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Fan and ventilation area|(% style="width:712px" %)Wipe carefully with a dry cloth. Replace heavily contaminated filter mats.
68 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction pre-filter, if fitted|(% style="width:712px" %)Inspect and replace when full.
69 +|(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction main filter, if fitted|(% style="width:712px" %)Inspect and replace when contaminated; shorten the interval for high process loads.
70 +
71 +(% class="box infomessage" %)
72 +(((
73 +Intervals are suggestions for default working environment. Increase inspection frequency for dusty environments or high utilization
74 +)))
75 +
76 +
77 +
78 +
79 += Avoiding Faults - Typical Causes and Remedies =
80 +
81 +(% class="table-condensed table-striped" %)
82 +|**Observation**|**Maintenance response**
83 +|Weak or inconsistent marking|Verify focus first; inspect the objective and protective glass for contamination; confirm the approved parameter set.
84 +|Thermal alarm or unstable operation|Check that cooling openings are clear, clean the ventilation area, inspect filter mats, and verify ambient conditions.
85 +|Deposits around the process area|Check extraction airflow and filter condition; clean surrounding surfaces and review the qualified process.
86 +|Visible optical damage|Stop operation. Do not attempt to polish scratches or continue with a cracked protective glass; contact service.
87 +
88 +
89 +
90 += After Maintenance - Return to Service =
91 +
92 +1. Confirm all covers, connectors, safeguards, and labels are installed and secure.
93 +1. Remove tools, tissues, solvents, and loose objects from the marking area.
94 +1. Restore power and verify the complete host-machine safety sequence, including emergency stop and shutter interlocks.
95 +1. Confirm cooling airflow and extraction operation.
96 +1. Perform a pilot-positioning check and a short test mark on an approved sample.