27 27  The Auto-Light is air-cooled. Filter mats protect the rack electronics from dust and contamination. Blocked openings or contaminated filter mats cause heat accumulation and can damage the system.
28 28  
29 -[[**Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.**>>image:1788756663547-478.png||height="275" width="589"]]
29 +[[//Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.//>>image:1788756663547-478.png||height="275" width="589"]]
30 30  
31 31  
32 32  1. Inspect the filter mats behind the front and rear ventilation openings and replace them when contaminated.
... ... @@ -44,8 +44,4 @@
44 44  1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container.
45 45  1. Wipe gently in a circular motion from the centre toward the edge. Keep the tissue moving and do not apply pressure.
46 46  1. Do not use tools or hard objects. Scratches cannot be repaired.
47 -1. If contamination cannot be removed safely, stop and contact service
48 -
49 -[[**Example F-Theta lens. Handle optical surfaces only with approved methods and materials.**>>image:1788757524363-116.png]]
50 -
51 -= Suggested Maintenance Intervals =
47 +1. If contamination cannot be removed safely, stop and contact service.