... ... @@ -12,6 +12,8 @@
12 12  1. Reinstall every cover, connection, warning label, and safety device before returning the integrated machine to service.
13 13  1. Do not use flammable or explosive cleaning agents in the processing area.
14 14  
15 +
16 +
15 15  = Daily Visual Check =
16 16  
17 17  1. Inspect the lens and objective protective glass; clean only when necessary.
... ... @@ -26,6 +26,39 @@
26 26  
27 27  The Auto-Light is air-cooled. Filter mats protect the rack electronics from dust and contamination. Blocked openings or contaminated filter mats cause heat accumulation and can damage the system.
28 28  
29 -[[//Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.//>>image:1788756663547-478.png]]
31 +[[**Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.**>>image:1788756663547-478.png||height="275" width="589"]]
30 30  
33 +
34 +1. Inspect the filter mats behind the front and rear ventilation openings and replace them when contaminated.
35 +1. Keep the surrounding area clean to reduce dust entering the cooling system and settling on optics.
36 +1. Operate suitable extraction whenever marking produces gases, vapors, aerosols, or dust.
37 +
38 +
39 +
40 += Cleaning Optical Components =
41 +
42 +Laser optics are easily damaged. Prevent contamination through effective extraction and a clean work area. Never touch optical surfaces with bare fingers.
43 +
44 +1. Isolate the system and prepare a clean work area.
45 +1. Remove loose dust with a small clean hand blower. Do not use workshop compressed air because it can contain oil or water.
46 +1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container.
47 +1. Wipe gently in a circular motion from the centre toward the edge. Keep the tissue moving and do not apply pressure.
48 +1. Do not use tools or hard objects. Scratches cannot be repaired.
49 +1. If contamination cannot be removed safely, stop and contact service
50 +
51 +
52 +
53 +[[**Example F-Theta lens. Handle optical surfaces only with approved methods and materials.**>>image:1788757524363-116.png]]
54 +
55 +
56 += Suggested Maintenance Intervals =
57 +
58 +(% class="table-condensed table-striped" %)
59 +|=**Interval**|=**Item**|=**Method**
60 +|Daily|Lens|
61 +|Monthly|Objective protective glass|
62 +|Monthly|Fan and ventilation area|
63 +|Monthly| |
64 +|Monthly| |
65 +