Changes for page Maintenance

Last modified by jadomatis on 2026/09/07 09:01

From version 4.1
edited by jadomatis
on 2026/09/07 06:58
Change comment: Uploaded new attachment "1788756663547-478.png", version {1}
To version 4.2
edited by jadomatis
on 2026/09/07 06:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,3 +11,21 @@
11 11  1. Do not remove, bypass, or modify safety-related components, the shutter, the laser head, or protective covers.
12 12  1. Reinstall every cover, connection, warning label, and safety device before returning the integrated machine to service.
13 13  1. Do not use flammable or explosive cleaning agents in the processing area.
14 +
15 += Daily Visual Check =
16 +
17 +1. Inspect the lens and objective protective glass; clean only when necessary.
18 +1. Check the laser head, fibre routing, connectors, and rack for visible damage.
19 +1. Confirm that warning and identification labels are present and legible.
20 +1. Keep the work area clean and verify that process-fume extraction is available.
21 +1. Ensure the front and rear cooling openings are unobstructed.
22 +
23 +
24 +
25 += Airflow, Filters, and Work Environment =
26 +
27 +The Auto-Light is air-cooled. Filter mats protect the rack electronics from dust and contamination. Blocked openings or contaminated filter mats cause heat accumulation and can damage the system.
28 +
29 +[[//Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.//>>image:1788756663547-478.png]]
30 +
31 +