Wiki source code of Maintenance
Last modified by jadomatis on 2026/09/07 09:01
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | **Description**: Learn how to maintain the Auto-Light optics, cooling airflow, filters and extraction systems to preserve safe operation and consistent marking quality. | ||
| 2 | |||
| 3 | {{toc/}} | ||
| 4 | |||
| 5 | ---- | ||
| 6 | |||
| 7 | (% class="box warningmessage" %) | ||
| 8 | ((( | ||
| 9 | **CAUTION: **Before maintenance, switch off and fully de-energize the system. Maintenance and repair beyond the operator tasks described here should be performed only by Schilling Marking Systems or authorized personnel. | ||
| 10 | ))) | ||
| 11 | |||
| 12 | |||
| 13 | = Responsibilities and Original Parts = | ||
| 14 | |||
| 15 | 1. Use original spare parts and approved consumables. Incompatible parts can impair safety and equipment reliability. | ||
| 16 | 1. Do not remove, bypass, or modify safety-related components, the shutter, the laser head, or protective covers. | ||
| 17 | 1. Reinstall every cover, connection, warning label, and safety device before returning the integrated machine to service. | ||
| 18 | 1. Do not use flammable or explosive cleaning agents in the processing area. | ||
| 19 | |||
| 20 | |||
| 21 | |||
| 22 | = Daily Visual Check = | ||
| 23 | |||
| 24 | 1. Inspect the lens and objective protective glass; clean only when necessary. | ||
| 25 | 1. Check the laser head, fiber routing, connectors, and rack for visible damage. | ||
| 26 | 1. Confirm that warning and identification labels are present and legible. | ||
| 27 | 1. Keep the work area clean and verify that process-fume extraction is available. | ||
| 28 | 1. Ensure the front and rear cooling openings are unobstructed. | ||
| 29 | |||
| 30 | |||
| 31 | |||
| 32 | = Airflow, Filters, and Work Environment = | ||
| 33 | |||
| 34 | The Auto-Light is air-cooled. Filter mats protect the rack electronics from dust and contamination. Blocked openings or contaminated filter mats cause heat accumulation and can damage the system. | ||
| 35 | |||
| 36 | [[**Auto-Light rack front. Keep approximately 15 cm clear at the cooling openings.**>>image:1788756663547-478.png||height="275" width="589"]] | ||
| 37 | |||
| 38 | |||
| 39 | 1. Inspect the filter mats behind the front and rear ventilation openings and replace them when contaminated. | ||
| 40 | 1. Keep the surrounding area clean to reduce dust entering the cooling system and settling on optics. | ||
| 41 | 1. Operate suitable extraction whenever marking produces gases, vapors, aerosols, or dust. | ||
| 42 | |||
| 43 | |||
| 44 | |||
| 45 | = Cleaning Optical Components = | ||
| 46 | |||
| 47 | Laser optics are easily damaged. Prevent contamination through effective extraction and a clean work area. Never touch optical surfaces with bare fingers. | ||
| 48 | |||
| 49 | 1. Isolate the system and prepare a clean work area. | ||
| 50 | 1. Remove loose dust with a small clean hand blower. Do not use workshop compressed air because it can contain oil or water. | ||
| 51 | 1. Apply a small quantity of approved cleaning solution to a soft, lint-free optical tissue. Do not dip the tissue into the solution container. | ||
| 52 | 1. Wipe gently in a circular motion from the center toward the edge. Keep the tissue moving and do not apply pressure. | ||
| 53 | 1. Do not use tools or hard objects. Scratches cannot be repaired. | ||
| 54 | 1. If contamination cannot be removed safely, stop and contact service | ||
| 55 | |||
| 56 | |||
| 57 | |||
| 58 | [[**Example F-Theta lens. Handle optical surfaces only with approved methods and materials.**>>image:1788757524363-116.png]] | ||
| 59 | |||
| 60 | |||
| 61 | = Suggested Maintenance Intervals = | ||
| 62 | |||
| 63 | (% class="table-condensed table-striped" %) | ||
| 64 | |=(% style="width: 234px;" %)**Interval**|=(% style="width: 262px;" %)**Item**|=(% style="width: 712px;" %)**Method** | ||
| 65 | |(% style="width:234px" %)Daily|(% style="width:262px" %)Lens|(% style="width:712px" %)Inspect and clean if necessary. | ||
| 66 | |(% style="width:234px" %)Monthly|(% style="width:262px" %)Objective protective glass|(% style="width:712px" %)Wipe carefully with a soft cloth and approved optical-cleaning agent. The source mentions acetone or diethyl ether; follow the chemical safety data and site rules. | ||
| 67 | |(% style="width:234px" %)Monthly|(% style="width:262px" %)Fan and ventilation area|(% style="width:712px" %)Wipe carefully with a dry cloth. Replace heavily contaminated filter mats. | ||
| 68 | |(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction pre-filter, if fitted|(% style="width:712px" %)Inspect and replace when full. | ||
| 69 | |(% style="width:234px" %)Monthly|(% style="width:262px" %)Extraction main filter, if fitted|(% style="width:712px" %)Inspect and replace when contaminated; shorten the interval for high process loads. | ||
| 70 | |||
| 71 | (% class="box infomessage" %) | ||
| 72 | ((( | ||
| 73 | Intervals are suggestions for default working environment. Increase inspection frequency for dusty environments or high utilization | ||
| 74 | ))) | ||
| 75 | |||
| 76 | |||
| 77 | |||
| 78 | |||
| 79 | = Avoiding Faults - Typical Causes and Remedies = | ||
| 80 | |||
| 81 | (% class="table-condensed table-striped" %) | ||
| 82 | |**Observation**|**Maintenance response** | ||
| 83 | |Weak or inconsistent marking|Verify focus first; inspect the objective and protective glass for contamination; confirm the approved parameter set. | ||
| 84 | |Thermal alarm or unstable operation|Check that cooling openings are clear, clean the ventilation area, inspect filter mats, and verify ambient conditions. | ||
| 85 | |Deposits around the process area|Check extraction airflow and filter condition; clean surrounding surfaces and review the qualified process. | ||
| 86 | |Visible optical damage|Stop operation. Do not attempt to polish scratches or continue with a cracked protective glass; contact service. | ||
| 87 | |||
| 88 | |||
| 89 | |||
| 90 | = After Maintenance - Return to Service = | ||
| 91 | |||
| 92 | 1. Confirm all covers, connectors, safeguards, and labels are installed and secure. | ||
| 93 | 1. Remove tools, tissues, solvents, and loose objects from the marking area. | ||
| 94 | 1. Restore power and verify the complete host-machine safety sequence, including emergency stop and shutter interlocks. | ||
| 95 | 1. Confirm cooling airflow and extraction operation. | ||
| 96 | 1. Perform a pilot-positioning check and a short test mark on an approved sample. |