| 1 | **Description**: Learn how to Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test. | ||
| 2 | |||
| 3 | (% class="box warningmessage" %) | ||
| 4 | ((( | ||
| 5 | **Class 4 integration laser: **Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person. | ||
| 6 | ))) | ||
| 7 | |||
| 8 | = Preconditions (Before Switching On) = | ||
| 9 | |||
| 10 | Confirm all of the following before applying power: | ||
| 11 | |||
| 12 | * Remove all packaging and transport restraints. Position the supplied equipment upright on a stable installation surface and complete the mechanical installation. | ||
| 13 | * Verify that the mains voltage and frequency match the delivered system data. Keep the rear main switch in the OFF position while making or checking connections. | ||
| 14 | * Inspect the mains cable and plug. Do not use the system if either is damaged, incorrectly specified, or insecurely connected. | ||
| 15 | * Confirm that the X1 safety and production interface is wired to the approved external safety circuit, including both emergency-stop channels and both shutter channels. | ||
| 16 | * Confirm that opening the protective enclosure or guard interrupts the shutter circuit. Test emergency-stop acknowledgement and all required safety-status signals before enabling laser operation. | ||
| 17 | * If X2-controlled axes are installed, verify the approved axis wiring, direction, step, and zero-signal configuration before commanding movement. | ||
| 18 | * Inspect any installed laser-protection window or enclosure glazing for damage. The protection must match the installed wavelength and power. | ||
| 19 | * Ensure the focusing objective and other optical components are clean and free from dust. Leave the objective protection cap in place until immediately before start-up. | ||
| 20 | * Provide unobstructed airflow at the 19-inch rack ventilation openings and filter mats. Do not operate the system if heat can accumulate. | ||
| 21 | * Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes. | ||
| 22 | * Start and verify the approved extraction system for the material and process before any test marking. | ||
| 23 | |||
| 24 | (% class="box warningmessage" %) | ||
| 25 | ((( | ||
| 26 | The Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements. | ||
| 27 | ))) | ||
| 28 | |||
| 29 | |||
| 30 | |||
| 31 | = Electrical Start-Up = | ||
| 32 | |||
| 33 | **Before starting: **Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted. | ||
| 34 | |||
| 35 | 1. Confirm that the integrated protective enclosure is closed, all safety circuits are ready, and extraction is running. | ||
| 36 | 1. Set the main switch on the rear of the Auto-Light rack to I (ON). | ||
| 37 | 1. Turn the laser key switch on the front of the rack to I. | ||
| 38 | 1. Observe the system status. If the system does not reach the expected ready state, switch it off and correct the cause before continuing. | ||
| 39 | |||
| 40 | [[image:1788521448348-845.png]] | ||
| 41 | |||
| 42 | |||
| 43 | |||
| 44 | |||
| 45 | [[image:1788521448357-184.png]] | ||
| 46 | |||
| 47 | |||
| 48 | \\Software and Device Connection | ||
| 49 | |||
| 50 | 1. Start the approved workstation and open AnyMarker Designer. | ||
| 51 | 1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available. | ||
| 52 | 1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting. | ||
| 53 | |||
| 54 | For software-specific steps, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. This article does not replace the current software instructions. | ||
| 55 | |||
| 56 | = Initial Checks With the Pilot Laser = | ||
| 57 | |||
| 58 | * Load or create an approved test layout in AnyMarker Designer. | ||
| 59 | * Use the Pilot function to display the marking field without production-laser emission. | ||
| 60 | * Verify the orientation and position of the projected field on the test workpiece while the protective enclosure remains closed. | ||
| 61 | * Stop if the pilot outline, axis movement, or workpiece position does not match the validated setup. | ||
| 62 | |||
| 63 | = Focus and Workpiece Positioning = | ||
| 64 | |||
| 65 | 1. Secure the test workpiece or fixture in the approved marking position. | ||
| 66 | 1. Adjust the electrically controlled Z-axis until the specified focus distance is reached. The correct focus distance is required for a permanent, legible mark. | ||
| 67 | 1. Use the pilot outline and the approved focus method to confirm the marking location and focus before permitting production-laser emission. | ||
| 68 | |||
| 69 | = First Functional Test = | ||
| 70 | |||
| 71 | 1. Select a verified parameter set for the test material and confirm that extraction is operating. | ||
| 72 | 1. With the protective enclosure closed and all safeguards active, perform a short test mark on an approved sample. | ||
| 73 | 1. Monitor the ready, busy, end, shutter, and emergency-stop status signals used by the integrated machine. | ||
| 74 | 1. Inspect the result for position, focus, legibility, contrast, and unwanted thermal effects. Correct the setup only after laser emission has stopped. | ||
| 75 | 1. Record the accepted hardware configuration, software/device connection, safety-test result, and approved marking parameters before handing the system over for operation. | ||
| 76 | |||
| 77 | (% class="box warningmessage" %) | ||
| 78 | ((( | ||
| 79 | **Stop immediately: **If a safeguard, shutter circuit, emergency-stop function, status signal, axis, extraction system, or optical component behaves unexpectedly, stop commissioning and isolate the equipment. Do not bypass the fault to complete the test. | ||
| 80 | ))) | ||
| 81 | |||
| 82 | = Controlled Shutdown After the Test = | ||
| 83 | |||
| 84 | 1. End the marking command and confirm that laser emission has stopped. | ||
| 85 | 1. Set the rear main switch to 0 (OFF). | ||
| 86 | 1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure. |