Wiki-Quellcode von Commisioning and First Start

Version 2.3 von jadomatis am 2026/09/04 13:40

Verstecke letzte Bearbeiter
jadomatis 2.3 1 **Description**: Learn how to Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test.
jadomatis 2.2 2
jadomatis 2.3 3 (% class="box warningmessage" %)
4 (((
jadomatis 2.2 5 **Class 4 integration laser: **Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person.
jadomatis 2.3 6 )))
jadomatis 2.2 7
8 = Preconditions (Before Switching On) =
9
10 Confirm all of the following before applying power:
11
12 * Remove all packaging and transport restraints. Position the supplied equipment upright on a stable installation surface and complete the mechanical installation.
13 * Verify that the mains voltage and frequency match the delivered system data. Keep the rear main switch in the OFF position while making or checking connections.
14 * Inspect the mains cable and plug. Do not use the system if either is damaged, incorrectly specified, or insecurely connected.
15 * Confirm that the X1 safety and production interface is wired to the approved external safety circuit, including both emergency-stop channels and both shutter channels.
16 * Confirm that opening the protective enclosure or guard interrupts the shutter circuit. Test emergency-stop acknowledgement and all required safety-status signals before enabling laser operation.
17 * If X2-controlled axes are installed, verify the approved axis wiring, direction, step, and zero-signal configuration before commanding movement.
18 * Inspect any installed laser-protection window or enclosure glazing for damage. The protection must match the installed wavelength and power.
19 * Ensure the focusing objective and other optical components are clean and free from dust. Leave the objective protection cap in place until immediately before start-up.
20 * Provide unobstructed airflow at the 19-inch rack ventilation openings and filter mats. Do not operate the system if heat can accumulate.
21 * Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes.
22 * Start and verify the approved extraction system for the material and process before any test marking.
23
jadomatis 2.3 24 (% class="box warningmessage" %)
25 (((
26 The Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements.
27 )))
jadomatis 2.2 28
29
jadomatis 2.3 30
jadomatis 2.2 31 = Electrical Start-Up =
32
33 **Before starting: **Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted.
34
35 1. Confirm that the integrated protective enclosure is closed, all safety circuits are ready, and extraction is running.
36 1. Set the main switch on the rear of the Auto-Light rack to I (ON).
37 1. Turn the laser key switch on the front of the rack to I.
38 1. Observe the system status. If the system does not reach the expected ready state, switch it off and correct the cause before continuing.
39
40 [[image:1788521448348-845.png]]
41
42
43
44
45 [[image:1788521448357-184.png]]
46
47
jadomatis 2.3 48 \\Software and Device Connection
jadomatis 2.2 49
50 1. Start the approved workstation and open AnyMarker Designer.
51 1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available.
52 1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting.
53
54 For software-specific steps, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. This article does not replace the current software instructions.
55
56 = Initial Checks With the Pilot Laser =
57
58 * Load or create an approved test layout in AnyMarker Designer.
59 * Use the Pilot function to display the marking field without production-laser emission.
60 * Verify the orientation and position of the projected field on the test workpiece while the protective enclosure remains closed.
61 * Stop if the pilot outline, axis movement, or workpiece position does not match the validated setup.
62
63 = Focus and Workpiece Positioning =
64
65 1. Secure the test workpiece or fixture in the approved marking position.
66 1. Adjust the electrically controlled Z-axis until the specified focus distance is reached. The correct focus distance is required for a permanent, legible mark.
67 1. Use the pilot outline and the approved focus method to confirm the marking location and focus before permitting production-laser emission.
68
69 = First Functional Test =
70
71 1. Select a verified parameter set for the test material and confirm that extraction is operating.
72 1. With the protective enclosure closed and all safeguards active, perform a short test mark on an approved sample.
73 1. Monitor the ready, busy, end, shutter, and emergency-stop status signals used by the integrated machine.
74 1. Inspect the result for position, focus, legibility, contrast, and unwanted thermal effects. Correct the setup only after laser emission has stopped.
75 1. Record the accepted hardware configuration, software/device connection, safety-test result, and approved marking parameters before handing the system over for operation.
76
77 (% class="box warningmessage" %)
78 (((
79 **Stop immediately: **If a safeguard, shutter circuit, emergency-stop function, status signal, axis, extraction system, or optical component behaves unexpectedly, stop commissioning and isolate the equipment. Do not bypass the fault to complete the test.
80 )))
81
82 = Controlled Shutdown After the Test =
83
84 1. End the marking command and confirm that laser emission has stopped.
85 1. Set the rear main switch to 0 (OFF).
86 1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.