Commissioning and First Start-Up
Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test.
Class 4 integration laser: Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person.
Preconditions (Before Switching On)
Confirm all of the following before applying power:
- Remove all packaging and transport restraints. Position the supplied equipment upright on a stable installation surface and complete the mechanical installation.
- Verify that the mains voltage and frequency match the delivered system data. Keep the rear main switch in the OFF position while making or checking connections.
- Inspect the mains cable and plug. Do not use the system if either is damaged, incorrectly specified, or insecurely connected.
- Confirm that the X1 safety and production interface is wired to the approved external safety circuit, including both emergency-stop channels and both shutter channels.
- Confirm that opening the protective enclosure or guard interrupts the shutter circuit. Test emergency-stop acknowledgement and all required safety-status signals before enabling laser operation.
- If X2-controlled axes are installed, verify the approved axis wiring, direction, step, and zero-signal configuration before commanding movement.
- Inspect any installed laser-protection window or enclosure glazing for damage. The protection must match the installed wavelength and power.
- Ensure the focusing objective and other optical components are clean and free from dust. Leave the objective protection cap in place until immediately before start-up.
- Provide unobstructed airflow at the 19-inch rack ventilation openings and filter mats. Do not operate the system if heat can accumulate.
- Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes.
- Start and verify the approved extraction system for the material and process before any test marking.
The Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements.
Electrical Start-Up
Before starting: Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted.
- Confirm that the integrated protective enclosure is closed, all safety circuits are ready, and extraction is running.
- Set the main switch on the rear of the Auto-Light rack to I (ON).
- Turn the laser key switch on the front of the rack to I.
- Observe the system status. If the system does not reach the expected ready state, switch it off and correct the cause before continuing.


Software and Device Connection
- Start the approved workstation and open AnyMarker Designer.
- Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available.
- If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting.
For software-specific steps, use the AnyMarker Designer XWiki. This article does not replace the current software instructions.
Initial Checks With the Pilot Laser
- Load or create an approved test layout in AnyMarker Designer.
- Use the Pilot function to display the marking field without production-laser emission.
- Verify the orientation and position of the projected field on the test workpiece while the protective enclosure remains closed.
- Stop if the pilot outline, axis movement, or workpiece position does not match the validated setup.
Focus and Workpiece Positioning
- Secure the test workpiece or fixture in the approved marking position.
- Adjust the electrically controlled Z-axis until the specified focus distance is reached. The correct focus distance is required for a permanent, legible mark.
- Use the pilot outline and the approved focus method to confirm the marking location and focus before permitting production-laser emission.
First Functional Test
- Select a verified parameter set for the test material and confirm that extraction is operating.
- With the protective enclosure closed and all safeguards active, perform a short test mark on an approved sample.
- Monitor the ready, busy, end, shutter, and emergency-stop status signals used by the integrated machine.
- Inspect the result for position, focus, legibility, contrast, and unwanted thermal effects. Correct the setup only after laser emission has stopped.
- Record the accepted hardware configuration, software/device connection, safety-test result, and approved marking parameters before handing the system over for operation.
Controlled Shutdown After the Test
- End the marking command and confirm that laser emission has stopped.
- Set the rear main switch to 0 (OFF).
- The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.