Changes for page Commisioning and First Start
Last modified by jadomatis on 2026/09/07 09:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,8 @@ 1 -** Description**: Learn how toCommissionthe Auto-Light safely after transport, installation, integration,or relocation. Complete every integration-safety check before power is applied,then perform the firstelectrical start-upand controlled functional test.1 +**Commissioning and First Start-Up** 2 2 3 - (%class="boxwarningmessage"%)4 - (((3 +Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test. 4 + 5 5 **Class 4 integration laser: **Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person. 6 -))) 7 7 8 8 = Preconditions (Before Switching On) = 9 9 ... ... @@ -21,13 +21,9 @@ 21 21 * Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes. 22 22 * Start and verify the approved extraction system for the material and process before any test marking. 23 23 24 -(% class="box warningmessage" %) 25 -((( 26 -The Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements. 27 -))) 23 +**T**he Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements. 28 28 29 29 30 - 31 31 = Electrical Start-Up = 32 32 33 33 **Before starting: **Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted. ... ... @@ -45,17 +45,15 @@ 45 45 [[image:1788521448357-184.png]] 46 46 47 47 43 + 48 48 = Software and Device Connection = 49 49 50 -1. ((( 51 -Start the approved workstation and open AnyMarker Designer. 52 -))) 46 +1. Start the approved workstation and open AnyMarker Designer. 53 53 1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available. 54 54 1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting. 55 55 56 56 For software-specific steps, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. This article does not replace the current software instructions. 57 57 58 - 59 59 = Initial Checks With the Pilot Laser = 60 60 61 61 * Load or create an approved test layout in AnyMarker Designer. ... ... @@ -63,8 +63,6 @@ 63 63 * Verify the orientation and position of the projected field on the test workpiece while the protective enclosure remains closed. 64 64 * Stop if the pilot outline, axis movement, or workpiece position does not match the validated setup. 65 65 66 - 67 - 68 68 = Focus and Workpiece Positioning = 69 69 70 70 1. Secure the test workpiece or fixture in the approved marking position. ... ... @@ -71,8 +71,6 @@ 71 71 1. Adjust the electrically controlled Z-axis until the specified focus distance is reached. The correct focus distance is required for a permanent, legible mark. 72 72 1. Use the pilot outline and the approved focus method to confirm the marking location and focus before permitting production-laser emission. 73 73 74 - 75 - 76 76 = First Functional Test = 77 77 78 78 1. Select a verified parameter set for the test material and confirm that extraction is operating. ... ... @@ -86,10 +86,8 @@ 86 86 **Stop immediately: **If a safeguard, shutter circuit, emergency-stop function, status signal, axis, extraction system, or optical component behaves unexpectedly, stop commissioning and isolate the equipment. Do not bypass the fault to complete the test. 87 87 ))) 88 88 89 - 90 - 91 91 = Controlled Shutdown After the Test = 92 92 93 93 1. End the marking command and confirm that laser emission has stopped. 94 -1. he operating manual permits theSet the rear main switch to 0 (OFF).95 -1. T front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure. 81 +1. Set the rear main switch to 0 (OFF). 82 +1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.