... ... @@ -45,14 +45,17 @@
45 45  [[image:1788521448357-184.png]]
46 46  
47 47  
48 -\\Software and Device Connection
48 += Software and Device Connection =
49 49  
50 -1. Start the approved workstation and open AnyMarker Designer.
50 +1. (((
51 +Start the approved workstation and open AnyMarker Designer.
52 +)))
51 51  1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available.
52 52  1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting.
53 53  
54 54  For software-specific steps, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. This article does not replace the current software instructions.
55 55  
58 +
56 56  = Initial Checks With the Pilot Laser =
57 57  
58 58  * Load or create an approved test layout in AnyMarker Designer.
... ... @@ -60,6 +60,8 @@
60 60  * Verify the orientation and position of the projected field on the test workpiece while the protective enclosure remains closed.
61 61  * Stop if the pilot outline, axis movement, or workpiece position does not match the validated setup.
62 62  
66 +
67 +
63 63  = Focus and Workpiece Positioning =
64 64  
65 65  1. Secure the test workpiece or fixture in the approved marking position.
... ... @@ -66,6 +66,8 @@
66 66  1. Adjust the electrically controlled Z-axis until the specified focus distance is reached. The correct focus distance is required for a permanent, legible mark.
67 67  1. Use the pilot outline and the approved focus method to confirm the marking location and focus before permitting production-laser emission.
68 68  
74 +
75 +
69 69  = First Functional Test =
70 70  
71 71  1. Select a verified parameter set for the test material and confirm that extraction is operating.
... ... @@ -79,8 +79,10 @@
79 79  **Stop immediately: **If a safeguard, shutter circuit, emergency-stop function, status signal, axis, extraction system, or optical component behaves unexpectedly, stop commissioning and isolate the equipment. Do not bypass the fault to complete the test.
80 80  )))
81 81  
89 +
90 +
82 82  = Controlled Shutdown After the Test =
83 83  
84 84  1. End the marking command and confirm that laser emission has stopped.
85 -1. Set the rear main switch to 0 (OFF).
86 -1. The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.
94 +1. he operating manual permits theSet the rear main switch to 0 (OFF).
95 +1. T front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.