Änderungen von Dokument Commisioning and First Start
Zuletzt geändert von jadomatis am 2026/09/07 09:02
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -1,9 +1,8 @@ 1 -** Description**: Learn how toCommissionthe Auto-Light safely after transport, installation, integration,or relocation. Complete every integration-safety check before power is applied,then perform the firstelectrical start-upand controlled functional test.1 +**Commissioning and First Start-Up** 2 2 3 - (%class="boxwarningmessage"%)4 - (((3 +Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test. 4 + 5 5 **Class 4 integration laser: **Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person. 6 -))) 7 7 8 8 = Preconditions (Before Switching On) = 9 9 ... ... @@ -21,13 +21,9 @@ 21 21 * Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes. 22 22 * Start and verify the approved extraction system for the material and process before any test marking. 23 23 24 -(% class="box warningmessage" %) 25 -((( 26 -The Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements. 27 -))) 23 +**T**he Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements. 28 28 29 29 30 - 31 31 = Electrical Start-Up = 32 32 33 33 **Before starting: **Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted. ... ... @@ -45,8 +45,9 @@ 45 45 [[image:1788521448357-184.png]] 46 46 47 47 48 -\\Software and Device Connection 49 49 44 += Software and Device Connection = 45 + 50 50 1. Start the approved workstation and open AnyMarker Designer. 51 51 1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available. 52 52 1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting.