Änderungen von Dokument Commisioning and First Start
Zuletzt geändert von jadomatis am 2026/09/07 09:02
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -1,8 +1,9 @@ 1 -**Commissioning and FirstStart-Up**1 +**Description**: Learn how to Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test. 2 2 3 - Commissionthe Auto-Light safelyafter transport, installation,integration, orrelocation. Complete everyintegration-safety check before power is applied, then performthefirst electricalstart-up and controlledfunctional test.4 - 3 +(% class="box warningmessage" %) 4 +((( 5 5 **Class 4 integration laser: **Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person. 6 +))) 6 6 7 7 = Preconditions (Before Switching On) = 8 8 ... ... @@ -20,9 +20,13 @@ 20 20 * Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes. 21 21 * Start and verify the approved extraction system for the material and process before any test marking. 22 22 23 -**T**he Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements. 24 +(% class="box warningmessage" %) 25 +((( 26 +The Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements. 27 +))) 24 24 25 25 30 + 26 26 = Electrical Start-Up = 27 27 28 28 **Before starting: **Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted. ... ... @@ -40,9 +40,8 @@ 40 40 [[image:1788521448357-184.png]] 41 41 42 42 48 +\\Software and Device Connection 43 43 44 -= Software and Device Connection = 45 - 46 46 1. Start the approved workstation and open AnyMarker Designer. 47 47 1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available. 48 48 1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting.