Änderungen von Dokument Commisioning and First Start

Zuletzt geändert von jadomatis am 2026/09/07 09:02

Von Version 2.2
bearbeitet von jadomatis
am 2026/09/04 13:39
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 2.3
bearbeitet von jadomatis
am 2026/09/04 13:40
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -1,8 +1,9 @@
1 -**Commissioning and First Start-Up**
1 +**Description**: Learn how to Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test.
2 2  
3 -Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test.
4 -
3 +(% class="box warningmessage" %)
4 +(((
5 5  **Class 4 integration laser: **Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person.
6 +)))
6 6  
7 7  = Preconditions (Before Switching On) =
8 8  
... ... @@ -20,9 +20,13 @@
20 20  * Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes.
21 21  * Start and verify the approved extraction system for the material and process before any test marking.
22 22  
23 -**T**he Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements.
24 +(% class="box warningmessage" %)
25 +(((
26 +The Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements.
27 +)))
24 24  
25 25  
30 +
26 26  = Electrical Start-Up =
27 27  
28 28  **Before starting: **Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted.
... ... @@ -40,9 +40,8 @@
40 40  [[image:1788521448357-184.png]]
41 41  
42 42  
48 +\\Software and Device Connection
43 43  
44 -= Software and Device Connection =
45 -
46 46  1. Start the approved workstation and open AnyMarker Designer.
47 47  1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available.
48 48  1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting.