... ... @@ -1,82 +1,0 @@
1 -**Commissioning and First Start-Up**
2 -
3 -Commission the Auto-Light safely after transport, installation, integration, or relocation. Complete every integration-safety check before power is applied, then perform the first electrical start-up and controlled functional test.
4 -
5 -**Class 4 integration laser: **Only trained and authorized personnel may commission the Auto-Light. Do not switch on the system until the protective enclosure, access safeguards, emergency-stop circuits, shutter circuits, emission warning, extraction, and all site-specific laser-safety measures have been completed, tested, documented, and accepted by an authorized person.
6 -
7 -= Preconditions (Before Switching On) =
8 -
9 -Confirm all of the following before applying power:
10 -
11 -* Remove all packaging and transport restraints. Position the supplied equipment upright on a stable installation surface and complete the mechanical installation.
12 -* Verify that the mains voltage and frequency match the delivered system data. Keep the rear main switch in the OFF position while making or checking connections.
13 -* Inspect the mains cable and plug. Do not use the system if either is damaged, incorrectly specified, or insecurely connected.
14 -* Confirm that the X1 safety and production interface is wired to the approved external safety circuit, including both emergency-stop channels and both shutter channels.
15 -* Confirm that opening the protective enclosure or guard interrupts the shutter circuit. Test emergency-stop acknowledgement and all required safety-status signals before enabling laser operation.
16 -* If X2-controlled axes are installed, verify the approved axis wiring, direction, step, and zero-signal configuration before commanding movement.
17 -* Inspect any installed laser-protection window or enclosure glazing for damage. The protection must match the installed wavelength and power.
18 -* Ensure the focusing objective and other optical components are clean and free from dust. Leave the objective protection cap in place until immediately before start-up.
19 -* Provide unobstructed airflow at the 19-inch rack ventilation openings and filter mats. Do not operate the system if heat can accumulate.
20 -* Confirm an ambient temperature of +15 °C to +35 °C and relative humidity no higher than 90%, non-condensing. Allow the system to return to room temperature after major temperature changes.
21 -* Start and verify the approved extraction system for the material and process before any test marking.
22 -
23 -**T**he Auto-Light may be switched on only after an authorized person has checked the complete integrated installation and confirmed that the laser-safety measures comply with the applicable requirements.
24 -
25 -
26 -= Electrical Start-Up =
27 -
28 -**Before starting: **Remove the protection cap from the laser objective. Never energize the laser with the objective cap fitted.
29 -
30 -1. Confirm that the integrated protective enclosure is closed, all safety circuits are ready, and extraction is running.
31 -1. Set the main switch on the rear of the Auto-Light rack to I (ON).
32 -1. Turn the laser key switch on the front of the rack to I.
33 -1. Observe the system status. If the system does not reach the expected ready state, switch it off and correct the cause before continuing.
34 -
35 -[[image:1788521448348-845.png]]
36 -
37 -
38 -
39 -
40 -[[image:1788521448357-184.png]]
41 -
42 -
43 -
44 -= Software and Device Connection =
45 -
46 -1. Start the approved workstation and open AnyMarker Designer.
47 -1. Verify communication with the Auto-Light controller and confirm that the expected device configuration and approved parameters are available.
48 -1. If communication is not established, stop the procedure, switch the Auto-Light off, and check the approved USB or Ethernet connection before restarting.
49 -
50 -For software-specific steps, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. This article does not replace the current software instructions.
51 -
52 -= Initial Checks With the Pilot Laser =
53 -
54 -* Load or create an approved test layout in AnyMarker Designer.
55 -* Use the Pilot function to display the marking field without production-laser emission.
56 -* Verify the orientation and position of the projected field on the test workpiece while the protective enclosure remains closed.
57 -* Stop if the pilot outline, axis movement, or workpiece position does not match the validated setup.
58 -
59 -= Focus and Workpiece Positioning =
60 -
61 -1. Secure the test workpiece or fixture in the approved marking position.
62 -1. Adjust the electrically controlled Z-axis until the specified focus distance is reached. The correct focus distance is required for a permanent, legible mark.
63 -1. Use the pilot outline and the approved focus method to confirm the marking location and focus before permitting production-laser emission.
64 -
65 -= First Functional Test =
66 -
67 -1. Select a verified parameter set for the test material and confirm that extraction is operating.
68 -1. With the protective enclosure closed and all safeguards active, perform a short test mark on an approved sample.
69 -1. Monitor the ready, busy, end, shutter, and emergency-stop status signals used by the integrated machine.
70 -1. Inspect the result for position, focus, legibility, contrast, and unwanted thermal effects. Correct the setup only after laser emission has stopped.
71 -1. Record the accepted hardware configuration, software/device connection, safety-test result, and approved marking parameters before handing the system over for operation.
72 -
73 -(% class="box warningmessage" %)
74 -(((
75 -**Stop immediately: **If a safeguard, shutter circuit, emergency-stop function, status signal, axis, extraction system, or optical component behaves unexpectedly, stop commissioning and isolate the equipment. Do not bypass the fault to complete the test.
76 -)))
77 -
78 -= Controlled Shutdown After the Test =
79 -
80 -1. End the marking command and confirm that laser emission has stopped.