Wiki-Quellcode von Auto-Light Technical Specifications
Zuletzt geändert von jadomatis am 2026/09/08 07:54
Zeige letzte Bearbeiter
| author | version | line-number | content |
|---|---|---|---|
| 1 | **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants. | ||
| 2 | |||
| 3 | {{toc/}} | ||
| 4 | |||
| 5 | (% class="box warningmessage" %) | ||
| 6 | ((( | ||
| 7 | **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values. | ||
| 8 | ))) | ||
| 9 | |||
| 10 | ---- | ||
| 11 | |||
| 12 | = System Identification = | ||
| 13 | |||
| 14 | (% class="table-condensed table-striped" %) | ||
| 15 | |**Property**|**Specification** | ||
| 16 | |System type|Integration laser | ||
| 17 | |Laser classification|Laser Class 4 | ||
| 18 | |Protection rating|IP21 | ||
| 19 | |Available variants|F20, F30, F50, M20, and M30 | ||
| 20 | |Cooling|Low-noise forced air | ||
| 21 | |Sound level|< 70 dB | ||
| 22 | |||
| 23 | |||
| 24 | |||
| 25 | = Principal Dimensions = | ||
| 26 | |||
| 27 | [[**Auto-Light principal dimensions and standard optical arrangement. Verify mounting and connector details against the delivered drawings.**>>image:1788844179033-844.png]] | ||
| 28 | |||
| 29 | |||
| 30 | = Laser-Source Variants = | ||
| 31 | |||
| 32 | (% class="table-condensed table-striped" %) | ||
| 33 | |**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality** | ||
| 34 | |F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5 | ||
| 35 | |F30|Pulsed fiber|30 W|1 mJ|M2 < 1.5 | ||
| 36 | |F50|Pulsed fiber|50 W|1 mJ|M2 < 1.8 | ||
| 37 | |M20|Pulsed MOPA fiber|20 W|0.7 mJ|M2 < 1.3 | ||
| 38 | |M30|Pulsed MOPA fiber|30 W|1 mJ|M2 < 1.3 | ||
| 39 | |||
| 40 | |||
| 41 | |||
| 42 | = Pulse and Electrical Data = | ||
| 43 | |||
| 44 | (% class="table-condensed table-striped" %) | ||
| 45 | |**Model**|**Wavelength**|**Pulse frequency**|**Pulse duration**|**Power consumption** | ||
| 46 | |F20|1060-1070 nm|20-60 kHz|100 ns|< 200 W | ||
| 47 | |F30|1060-1070 nm|30-60 kHz|100 ns|< 300 W | ||
| 48 | |F50|1060-1070 nm|50-100 kHz|100 ns|< 340 W | ||
| 49 | |M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W | ||
| 50 | |M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W | ||
| 51 | |||
| 52 | (% class="box infomessage" %) | ||
| 53 | ((( | ||
| 54 | **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration. | ||
| 55 | ))) | ||
| 56 | |||
| 57 | |||
| 58 | |||
| 59 | = Common Optical and Mechanical Data = | ||
| 60 | |||
| 61 | (% class="table-condensed table-striped" %) | ||
| 62 | |**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30** | ||
| 63 | |Fibre length|m|3 | ||
| 64 | |Standard lens|-|F-Theta, 160 mm focal length | ||
| 65 | |Standard working distance|mm|176 | ||
| 66 | |Standard field size|mm|110 x 110 | ||
| 67 | |Lens wavelength|nm|1064 | ||
| 68 | |Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162 | ||
| 69 | |Laser-head dimensions|mm|367 x 131 x 131 | ||
| 70 | |||
| 71 | (% class="box warningmessage" %) | ||
| 72 | ((( | ||
| 73 | **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary. | ||
| 74 | ))) | ||
| 75 | |||
| 76 | |||
| 77 | |||
| 78 | = Operating and Installation Conditions = | ||
| 79 | |||
| 80 | (% class="table-condensed table-striped" %) | ||
| 81 | |**Condition**|**Requirement** | ||
| 82 | |Ambient temperature|+15 degrees C to +35 degrees C | ||
| 83 | |Relative humidity|No higher than 90%, non-condensing | ||
| 84 | |After a major temperature change|Allow the system to return to room temperature before commissioning | ||
| 85 | |Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats | ||
| 86 | |Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up | ||
| 87 | |Process emissions|Provide extraction suitable for the material, fumes, vapors, dust, and particles produced | ||
| 88 | |||
| 89 | |||
| 90 | |||
| 91 | = Interfaces and Supply - Overview = | ||
| 92 | |||
| 93 | (% class="table-condensed table-striped" %) | ||
| 94 | |**Connection**|**Description**|**Purpose** | ||
| 95 | |X0|230 V / 600 W, including main switch|Mains-supply interface | ||
| 96 | |X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O | ||
| 97 | |X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND | ||
| 98 | |X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND | ||
| 99 | |Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration | ||
| 100 | |||
| 101 | (% class="box errormessage" %) | ||
| 102 | ((( | ||
| 103 | **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel. | ||
| 104 | ))) | ||
| 105 | |||
| 106 | |||
| 107 | |||
| 108 | = Verification Before Use = | ||
| 109 | |||
| 110 | * Match the model designation and serial number to the nameplate and order documentation. | ||
| 111 | * Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept. | ||
| 112 | * Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring. | ||
| 113 | * Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards. | ||
| 114 | * Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes. | ||