Version 2.5 von jadomatis am 2026/09/08 07:52

Zeige letzte Bearbeiter
1 **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2
3 (% class="box warningmessage" %)
4 (((
5 **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
6 )))
7
8 ----
9
10 = System Identification =
11
12 (% class="table-condensed table-striped" %)
13 |**Property**|**Manual specification**
14 |System type|Integration laser
15 |Laser classification|Laser Class 4
16 |Protection rating|IP21
17 |Available variants|F20, F30, F50, M20, and M30
18 |Cooling|Low-noise forced air
19 |Sound level|< 70 dB
20
21
22
23 = Principal Dimensions =
24
25 [[**Auto-Light principal dimensions and standard optical arrangement. Verify mounting and connector details against the delivered drawings.**>>image:1788844179033-844.png]]
26
27
28 = Laser-Source Variants =
29
30 The F models use a pulsed fiber laser. The M models use a pulsed MOPA fiber laser. Values in both tables are reproduced from the manual's data sheet.
31
32 (% class="table-condensed table-striped" %)
33 |**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality**
34 |F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5
35 |F30|Pulsed fiber|30 W|1 mJ|M2 < 1.5
36 |F50|Pulsed fiber|50 W|1 mJ|M2 < 1.8
37 |M20|Pulsed MOPA fiber|20 W|0.7 mJ|M2 < 1.3
38 |M30|Pulsed MOPA fiber|30 W|1 mJ|M2 < 1.3
39
40
41
42 = Pulse and Electrical Data =
43
44 (% class="table-condensed table-striped" %)
45 |**Model**|**Wavelength**|**Pulse frequency**|**Pulse duration**|**Power consumption**
46 |F20|1060-1070 nm|20-60 kHz|100 ns|< 200 W
47 |F30|1060-1070 nm|30-60 kHz|100 ns|< 300 W
48 |F50|1060-1070 nm|50-100 kHz|100 ns|< 340 W
49 |M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W
50 |M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W
51
52 (% class="box infomessage" %)
53 (((
54 **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.
55 )))
56
57
58
59 = Common Optical and Mechanical Data =
60
61 (% class="table-condensed table-striped" %)
62 |**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30**
63 |Fibre length|m|3
64 |Standard lens|-|F-Theta, 160 mm focal length
65 |Standard working distance|mm|176
66 |Standard field size|mm|110 x 110
67 |Lens wavelength|nm|1064
68 |Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
69 |Laser-head dimensions|mm|367 x 131 x 131
70
71 (% class="box warningmessage" %)
72 (((
73 **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
74 )))
75
76
77
78 = Operating and Installation Conditions =
79
80 (% class="table-condensed table-striped" %)
81 |**Condition**|**Requirement**
82 |Ambient temperature|+15 degrees C to +35 degrees C
83 |Relative humidity|No higher than 90%, non-condensing
84 |After a major temperature change|Allow the system to return to room temperature before commissioning
85 |Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 |Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 |Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
88
89
90
91 = Interfaces and Supply - Overview =
92
93 (% class="table-condensed table-striped" %)
94 |**Connection**|**Manual description**|**Purpose**
95 |X0|230 V / 600 W, including main switch|Mains-supply interface
96 |X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
97 |X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
98 |X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
99 |Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
100
101 (% class="box errormessage" %)
102 (((
103
104 )))