1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 -/t
4 -
5 5  (% class="box warningmessage" %)
6 6  (((
7 7  **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
... ... @@ -70,49 +70,4 @@
70 70  |Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
71 71  |Laser-head dimensions|mm|367 x 131 x 131
72 72  
73 -(% class="box warningmessage" %)
74 -(((
75 - **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
76 -)))
77 -
78 -
79 -
80 -= Operating and Installation Conditions =
81 -
82 -(% class="table-condensed table-striped" %)
83 -|**Condition**|**Requirement**
84 -|Ambient temperature|+15 degrees C to +35 degrees C
85 -|Relative humidity|No higher than 90%, non-condensing
86 -|After a major temperature change|Allow the system to return to room temperature before commissioning
87 -|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
88 -|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
89 -|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
90 -
91 -
92 -
93 -= Interfaces and Supply - Overview =
94 -
95 -(% class="table-condensed table-striped" %)
96 -|**Connection**|**Manual description**|**Purpose**
97 -|X0|230 V / 600 W, including main switch|Mains-supply interface
98 -|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
99 -|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
100 -|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
101 -|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
102 -
103 -(% class="box errormessage" %)
104 -(((
105 - **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.
106 -)))
107 -
108 -
109 -
110 -= Verification Before Use =
111 -
112 -* Match the model designation and serial number to the nameplate and order documentation.
113 -* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
114 -* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
115 -* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.