Änderungen von Dokument Auto-Light Technical Specifications

Zuletzt geändert von jadomatis am 2026/09/08 07:54

Von Version 2.5
bearbeitet von jadomatis
am 2026/09/08 07:52
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 2.2
bearbeitet von jadomatis
am 2026/09/08 07:20
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -49,56 +49,4 @@
49 49  |M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W
50 50  |M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W
51 51  
52 -(% class="box infomessage" %)
53 -(((
54 - **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.
55 -)))
56 -
57 -
58 -
59 -= Common Optical and Mechanical Data =
60 -
61 -(% class="table-condensed table-striped" %)
62 -|**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30**
63 -|Fibre length|m|3
64 -|Standard lens|-|F-Theta, 160 mm focal length
65 -|Standard working distance|mm|176
66 -|Standard field size|mm|110 x 110
67 -|Lens wavelength|nm|1064
68 -|Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
69 -|Laser-head dimensions|mm|367 x 131 x 131
70 -
71 -(% class="box warningmessage" %)
72 -(((
73 - **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
74 -)))
75 -
76 -
77 -
78 -= Operating and Installation Conditions =
79 -
80 -(% class="table-condensed table-striped" %)
81 -|**Condition**|**Requirement**
82 -|Ambient temperature|+15 degrees C to +35 degrees C
83 -|Relative humidity|No higher than 90%, non-condensing
84 -|After a major temperature change|Allow the system to return to room temperature before commissioning
85 -|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 -|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 -|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
88 -
89 -
90 -
91 -= Interfaces and Supply - Overview =
92 -
93 -(% class="table-condensed table-striped" %)
94 -|**Connection**|**Manual description**|**Purpose**
95 -|X0|230 V / 600 W, including main switch|Mains-supply interface
96 -|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
97 -|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
98 -|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
99 -|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
100 -
101 -(% class="box errormessage" %)
102 -(((
103 103  
104 -)))