1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 +/t
4 +
3 3  (% class="box warningmessage" %)
4 4  (((
5 5  **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
... ... @@ -86,4 +86,31 @@
86 86  |Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 87  |Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
88 88  
91 +
92 +
93 += Interfaces and Supply - Overview =
94 +
95 +(% class="table-condensed table-striped" %)
96 +|**Connection**|**Manual description**|**Purpose**
97 +|X0|230 V / 600 W, including main switch|Mains-supply interface
98 +|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
99 +|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
100 +|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
101 +|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
102 +
103 +(% class="box errormessage" %)
104 +(((
105 + **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.
106 +)))
107 +
108 +
109 +
110 += Verification Before Use =
111 +
112 +* Match the model designation and serial number to the nameplate and order documentation.
113 +* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
114 +* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
115 +* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.
116 +* Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes.
117 +