Changes for page Auto-Light Technical Specifications
Last modified by jadomatis on 2026/09/08 07:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -86,4 +86,19 @@ 86 86 |Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up 87 87 |Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced 88 88 89 + 90 + 91 += Interfaces and Supply - Overview = 92 + 93 +(% class="table-condensed table-striped" %) 94 +|**Connection**|**Manual description**|**Purpose** 95 +|X0|230 V / 600 W, including main switch|Mains-supply interface 96 +|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O 97 +|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND 98 +|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND 99 +|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration 100 + 101 +(% class="box errormessage" %) 102 +((( 89 89 104 +)))