Changes for page Auto-Light Technical Specifications
Last modified by jadomatis on 2026/09/08 07:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -68,22 +68,4 @@ 68 68 |Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162 69 69 |Laser-head dimensions|mm|367 x 131 x 131 70 70 71 -(% class="box warningmessage" %) 72 -((( 73 - **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary. 74 -))) 75 - 76 - 77 - 78 -= Operating and Installation Conditions = 79 - 80 -(% class="table-condensed table-striped" %) 81 -|**Condition**|**Requirement** 82 -|Ambient temperature|+15 degrees C to +35 degrees C 83 -|Relative humidity|No higher than 90%, non-condensing 84 -|After a major temperature change|Allow the system to return to room temperature before commissioning 85 -|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats 86 -|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up 87 -|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced 88 - 89 89