Änderungen von Dokument Auto-Light Technical Specifications
Zuletzt geändert von jadomatis am 2026/09/08 07:54
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -1,5 +1,7 @@ 1 1 **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants. 2 2 3 +/t 4 + 3 3 (% class="box warningmessage" %) 4 4 ((( 5 5 **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values. ... ... @@ -68,4 +68,49 @@ 68 68 |Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162 69 69 |Laser-head dimensions|mm|367 x 131 x 131 70 70 73 +(% class="box warningmessage" %) 74 +((( 75 + **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary. 76 +))) 77 + 78 + 79 + 80 += Operating and Installation Conditions = 81 + 82 +(% class="table-condensed table-striped" %) 83 +|**Condition**|**Requirement** 84 +|Ambient temperature|+15 degrees C to +35 degrees C 85 +|Relative humidity|No higher than 90%, non-condensing 86 +|After a major temperature change|Allow the system to return to room temperature before commissioning 87 +|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats 88 +|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up 89 +|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced 90 + 91 + 92 + 93 += Interfaces and Supply - Overview = 94 + 95 +(% class="table-condensed table-striped" %) 96 +|**Connection**|**Manual description**|**Purpose** 97 +|X0|230 V / 600 W, including main switch|Mains-supply interface 98 +|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O 99 +|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND 100 +|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND 101 +|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration 102 + 103 +(% class="box errormessage" %) 104 +((( 105 + **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel. 106 +))) 107 + 108 + 109 + 110 += Verification Before Use = 111 + 112 +* Match the model designation and serial number to the nameplate and order documentation. 113 +* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept. 114 +* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring. 115 +* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards. 116 +* Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes. 117 + 71 71