... ... @@ -68,4 +68,22 @@
68 68  |Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
69 69  |Laser-head dimensions|mm|367 x 131 x 131
70 70  
71 +(% class="box warningmessage" %)
72 +(((
73 + **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
74 +)))
75 +
76 +
77 +
78 += Operating and Installation Conditions =
79 +
80 +(% class="table-condensed table-striped" %)
81 +|**Condition**|**Requirement**
82 +|Ambient temperature|+15 degrees C to +35 degrees C
83 +|Relative humidity|No higher than 90%, non-condensing
84 +|After a major temperature change|Allow the system to return to room temperature before commissioning
85 +|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 +|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 +|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
88 +