... ... @@ -49,4 +49,41 @@
49 49  |M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W
50 50  |M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W
51 51  
52 +(% class="box infomessage" %)
53 +(((
54 + **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.
55 +)))
56 +
57 +
58 +
59 += Common Optical and Mechanical Data =
60 +
61 +(% class="table-condensed table-striped" %)
62 +|**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30**
63 +|Fibre length|m|3
64 +|Standard lens|-|F-Theta, 160 mm focal length
65 +|Standard working distance|mm|176
66 +|Standard field size|mm|110 x 110
67 +|Lens wavelength|nm|1064
68 +|Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
69 +|Laser-head dimensions|mm|367 x 131 x 131
70 +
71 +(% class="box warningmessage" %)
72 +(((
73 + **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
74 +)))
75 +
76 +
77 +
78 += Operating and Installation Conditions =
79 +
80 +(% class="table-condensed table-striped" %)
81 +|**Condition**|**Requirement**
82 +|Ambient temperature|+15 degrees C to +35 degrees C
83 +|Relative humidity|No higher than 90%, non-condensing
84 +|After a major temperature change|Allow the system to return to room temperature before commissioning
85 +|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 +|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 +|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
88 +
52 52